The PWM capture assumes that the input selector is set to default
input and that the slave mode is disabled. Force reset state for
TISEL and SMCR registers to match this requirement.
Note that slave mode disabling is not a pre-requisite by itself
for capture mode, as hardware supports it for PWM capture.
However, the current implementation of the driver does not
allow slave mode for PWM capture. Setting slave mode for PWM
capture results in wrong capture values.
Signed-off-by: Olivier Moysan <olivier.moysan@foss.st.com>
Acked-by: Lee Jones <lee@kernel.org>
Acked-by: Uwe Kleine-König <u.kleine-koenig@pengutronix.de>
Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
The STM32 timer permits configuration of the counter encoder mode via
the slave mode control register (SMCR) slave mode selection (SMS) bits.
This patch provides preprocessor defines for the supported encoder
modes.
Cc: Fabrice Gasnier <fabrice.gasnier@foss.st.com>
Signed-off-by: William Breathitt Gray <vilhelm.gray@gmail.com>
Reviewed-by: Fabrice Gasnier <fabrice.gasnier@foss.st.com>
Link: https://lore.kernel.org/r/ad3d9cd7af580d586316d368f74964cbc394f981.1630031207.git.vilhelm.gray@gmail.com
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Remove usage of the ternary operator to assign values for register
fields. Instead, parameterize the register and field offset macros
and pass the index to them.
This removes clutter and improves readability.
Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
This is seen when COMPILE_TEST=y and MFD_STM32_TIMERS=n.
drivers/pwm/pwm-stm32.o: In function 'stm32_pwm_raw_capture':
pwm-stm32.c:... undefined reference to 'stm32_timers_dma_burst_read'
Fixes: 0c6609805b ("mfd: stm32-timers: Add support for DMAs")
Signed-off-by: Fabrice Gasnier <fabrice.gasnier@st.com>
Reported-by: Randy Dunlap <rdunlap@infradead.org>
Tested-by: Randy Dunlap <rdunlap@infradead.org>
Signed-off-by: Lee Jones <lee.jones@linaro.org>
Using input prescaler, capture unit will trigger DMA once every
configurable /2, /4 or /8 events (rising edge). This helps improve
period (only) capture accuracy at high rates.
Signed-off-by: Fabrice Gasnier <fabrice.gasnier@st.com>
Reviewed-by: Benjamin Gaignard <benjamin.gaignard@linaro.org>
Acked-by: Thierry Reding <thierry.reding@gmail.com>
Signed-off-by: Lee Jones <lee.jones@linaro.org>
Add support for PMW input mode on pwm-stm32. STM32 timers support
period and duty cycle capture as long as they have at least two PWM
channels. One capture channel is used for period (rising-edge), one
for duty-cycle (falling-edge).
When there's only one channel available, only period can be captured.
Duty-cycle is simply zero'ed in such a case.
Capture requires exclusive access (e.g. no pwm output running at the
same time, to protect common prescaler).
Timer DMA burst mode (from MFD core) is being used, to take two
snapshots of capture registers (upon each period rising edge).
Signed-off-by: Fabrice Gasnier <fabrice.gasnier@st.com>
Reviewed-by: Benjamin Gaignard <benjamin.gaignard@linaro.org>
Acked-by: Thierry Reding <thierry.reding@gmail.com>
Signed-off-by: Lee Jones <lee.jones@linaro.org>
STM32 Timers can support up to 7 DMA requests:
- 4 channels, update, compare and trigger.
Optionally request part, or all DMAs from stm32-timers MFD core.
Also add routine to implement burst reads using DMA from timer registers.
This is exported. So, it can be used by child drivers, PWM capture
for instance (but not limited to).
Signed-off-by: Fabrice Gasnier <fabrice.gasnier@st.com>
Reviewed-by: Benjamin Gaignard <benjamin.gaignard@linaro.org>
Signed-off-by: Lee Jones <lee.jones@linaro.org>
Add SPDX identifier
Signed-off-by: Benjamin Gaignard <benjamin.gaignard@st.com>
Acked-by: Philippe Ombredanne <pombredanne@nexb.com>
Signed-off-by: Lee Jones <lee.jones@linaro.org>
Add support for TRGO2 trigger that can be found on STM32F7.
Add additional master modes supported by TRGO2.
Register additional "tim[1/8]_trgo2" triggers for timer1 & timer8.
Detect TRGO2 timer capability (master mode selection 2).
Signed-off-by: Fabrice Gasnier <fabrice.gasnier@st.com>
Acked-by: Benjamin Gaignard <benjamin.gaignard@linaro.org>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
One of the features of STM32 trigger hardware block is a quadrature
encoder that can counts up/down depending of the levels and edges
of the selected external pins.
This patch allow to read/write the counter, get it direction,
set/get quadrature modes and get scale factor.
When counting up preset value is the limit of the counter.
When counting down the counter start from preset value down to 0.
This preset value could be set/get by using
/sys/bus/iio/devices/iio:deviceX/in_count0_preset attribute.
Signed-off-by: Benjamin Gaignard <benjamin.gaignard@st.com>
Reviewed-by: William Breathitt Gray <vilhelm.gray@gmail.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
This hardware block could at used at same time for PWM generation
and IIO timers.
PWM and IIO timer configuration are mixed in the same registers
so we need a multi fonction driver to be able to share those registers.
version 7:
- rebase on v4.10-rc2
version 6:
- rename files to stm32-timers
- rename functions to stm32_timers_xxx
version 5:
- fix Lee comments about detect function
- add missing dependency on REGMAP_MMIO
version 4:
- add a function to detect Auto Reload Register (ARR) size
- rename the structure shared with other drivers
version 2:
- rename driver "stm32-gptimer" to be align with SoC documentation
- only keep one compatible
- use of_platform_populate() instead of devm_mfd_add_devices()
Signed-off-by: Benjamin Gaignard <benjamin.gaignard@st.com>
Acked-by: Rob Herring <robh@kernel.org>
Signed-off-by: Lee Jones <lee.jones@linaro.org>