Author SHA1 Message Date
Guenter Roeck c5e6763667 hwmon: (pmbus/adm1275) Add support for second current limit
ADM1275 supports a second current limit, which can be configured as either lower
or upper limit. Add support for it and report it as either lower or upper
critical current limit.

Also replace error return code EINVAL for unsupported pages with ENXIO as this
is more appropriate for the observed condition.

Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Acked-by: Jean Delvare <khali@linux-fr.org>
2011-10-24 11:09:34 -07:00
Guenter Roeck 866cf12a0e hwmon: (pmbus) Don't return errors from driver remove functions
Driver remove functions have an error return value, but rarely return an error
in practice. If a driver does return an error from its remove function, the
driver won't be unloaded and is expected to stay alive.

pmbus_do_remove() is defined as returning an int, but always returns 0 (no
error). Calling code passes that return value on to high level driver
remove functions, but does not evaluate it and removes driver data even if
pmbus_do_remove() returned an error (which it in practice never does). Even if
this code could never cause a real problem, it is nevertheless conceptually
wrong.

To reduce confusion and simplify the code, change pmbus_do_remove() to be a void
function, and have PMBus client drivers always return zero in their driver
remove functions.

Reported-by: Jean Delvare <khali@linux-fr.org>
Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Acked-by: Jean Delvare <khali@linux-fr.org>
2011-10-24 11:09:33 -07:00
Guenter Roeck 20fcfe1721 hwmon: (pmbus) Add comments explaining internal driver API return values
Return values for functions reading/writing manufacturer specific registers are
poorly explained. Add comments to improve documentation.

Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Acked-by: Jean Delvare <khali@linux-fr.org>
2011-10-24 11:09:33 -07:00
Guenter Roeck 40257b953f hwmon: (pmbus) Fix low limit temperature alarms
Temperature alarms are detected by checking the alarm bit and comparing
temperature limits against the current temperature. For low limits, this
comparison needs to be reversed (temp < limit instead of temp > limit).
This was not taken into account, resulting in wrong alarms if a temperature
fell below a low limit.

Fix by adding a low limit flag in the limit data structure. When creating the
sensor entry, the order of registers to compare is now reversed for low limits.

Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Acked-by: Jean Delvare <khali@linux-fr.org>
Cc: stable@kernel.org # 3.0+
2011-09-13 06:19:15 -07:00
Jean Delvare f020b007d5 hwmon: (ucd9000/ucd9200) Optimize array walk
Rewrite the loop walking the id array during probe. The new code is
better adapted to a null-terminated array, and is also clearer and
more efficient than the original.

Signed-off-by: Jean Delvare <khali@linux-fr.org>
Cc: Axel Lin <axel.lin@gmail.com>
Cc: Guenter Roeck <guenter.roeck@ericsson.com>
Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
2011-09-06 08:56:07 -07:00
Guenter Roeck 3a2805e845 hwmon: (pmbus/lm25066) Ignore byte writes to non-zero pages
pmbus_clear_faults() attempts to clear faults on non-existing real pages.
As a result, the command error bit in the status register is set, and faults
are not really cleared.

All byte writes to non-zero pages are requests to clear the status register
on that page. Since non-zero pages are virtual and do not exist on the chip,
there is nothing to do, and such requests have to be ignored. This fixes
above problem.

Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
2011-08-11 10:14:12 -07:00
Guenter Roeck 044cd3a574 hwmon: (pmbus) Virtualize pmbus_write_byte
With virtual pages and to be able to handle more chips, it is necessary to
virtualise pmbus_write_byte().

Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
2011-08-11 10:14:04 -07:00
Guenter Roeck 03e9bd8dbc hwmon: (pmbus) Add client driver for LM25066, LM5064, and LM5066
PMBus client driver supporting National Semiconductor LM25066, LM5064, and LM5066.

Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
2011-07-28 20:16:17 -07:00
Guenter Roeck 98591dbe63 hwmon: (max34440) Add support for peak attributes
Add support for voltage, current, and temperature peak (historic maximum)
attributes.

Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
2011-07-28 17:09:54 -07:00
Guenter Roeck 70e94b276c hwmon: (max8688) Add support for peak attributes
Add support for voltage, current, and temperature peak (historic maximum)
attributes.

Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
2011-07-28 17:09:53 -07:00
Guenter Roeck 8ebed85450 hwmon: (max16064) Add support for peak attributes
Add support for voltage and temperature peak (historic maximum) attributes.

Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
2011-07-28 17:09:53 -07:00
Guenter Roeck c576e30cd0 hwmon: (adm1275) Add support for peak attributes
Add support for voltage and current peak (historic maximum) attributes.

Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
2011-07-28 17:09:52 -07:00
Guenter Roeck 6f183d33a0 hwmon: (pmbus) Add support for peak attributes
Most PMBus devices provide manufacturer specific commands to read low and/or
high peak values for some or all of its sensors.

To support providing those values as lowest/highest attributes to the user,
introduce virtual PMBus commands. Those commands reside outside the normal
command set and have to be implemented in device specific code, which map the
virtual commands to device specific commands.

Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
2011-07-28 17:09:32 -07:00
Guenter Roeck c6bfb767e4 hwmon: (pmbus) Strengthen check for status register existence
With virtual register page support, it is now possible that the status register
on virtual pages does not exist or is itself virtual. To take this into account
when creating alarm attributes, generate those attributes only if the status
register on the respective page is known to exist.

Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
2011-07-28 17:02:40 -07:00
Guenter Roeck 9c1ed8941d hwmon: (pmbus) Add support for virtual pages
Some PMBus chips have non-standard sensor registers. An easy way to
support such sensors is to introduce virtual pages and map the non-standard
registers into standard registers on an extra page.

For this to work, the code verifying if the configured number of pages exists
has to be removed. Since a wrong number of pages can only be configured in a
front-end driver, this should not have a practical impact since the resulting
errors should be found during development and testing.

Also, functions to read the chip status while checking if a command register
exists must be modified to no longer set the page register before reading the
status, since the physical page associated with the checked register may not
exist. This does not make a functional difference since the page was already set
when the attempt to read the register was made.

Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
2011-07-28 17:02:15 -07:00
Guenter Roeck 46243f3ab4 hwmon: (pmbus) Support reading and writing of word registers in device specific code
Some PMBus devices use non-standard registers for some of the sensors and/or
limits. To support such devices, add code to support reading and writing of word
size registers in device specific code.

Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
2011-07-28 16:55:13 -07:00
Guenter Roeck 2bd05bf4d2 hwmon: (pmbus) Increase attribute name size
Some hwmon sysfs attributes have a length of 20 bytes (plus terminating 0).
I2C_NAME_SIZE is defined as 20 and thus can not be used to define the length
of hwmon sysfs attributes. Replace it with PMBUS_NAME_SIZE, set to 24.

Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
2011-07-28 15:31:18 -07:00
Guenter Roeck e0455e380b hwmon: (pmbus) Add ADP4000, NCP4200 and NCP4208 to list of supported devices
Add ADP4000, NCP4200 and NCP4208 to the list of devices supported by the generic
PMBus driver, and add device IDs to enable explicit instantiation.

Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
Acked-by: Jean Delvare <khali@linux-fr.org>
2011-07-28 15:31:18 -07:00
Guenter Roeck 1061d8518f hwmon: (pmbus) Add support for VID output voltage mode
In VID mode, output voltages are measured and reported as VID values, and
have to be converted to voltages using VID conversion tables or functions.
Support is added for VR11 only at this time.

This patch enables support for PMBus devices supporting VID VR11 based output
voltage selection such as NCP4200 and NCP4208.

Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
2011-07-28 15:31:11 -07:00
Guenter Roeck 9d2ecfb768 hwmon: (pmbus) Move PMBus drivers to drivers/hwmon/pmbus
Since the number of PMBus drivers is getting large, move them into
directory drivers/hwmon/pmbus to improve readability and scalability.

Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
2011-07-28 11:47:53 -07:00