[ Upstream commit e95fa7404716f6e25021e66067271a4ad8eb1486 ]
Commit 0952177f2a ("thermal/core/power_allocator: Update once
cooling devices when temp is low") adds an update flag to avoid
triggering a thermal event when there is no need, and the thermal
cdev is updated once when the temperature is low.
But when the trips are writable, and switch_on_temp is set to be a
higher value, the cooling device state may not be reset to 0,
because last_temperature is smaller than switch_on_temp.
For example:
First:
switch_on_temp=70 control_temp=85;
Then userspace change the trip_temp:
switch_on_temp=45 control_temp=55 cur_temp=54
Then userspace reset the trip_temp:
switch_on_temp=70 control_temp=85 cur_temp=57 last_temp=54
At this time, the cooling device state should be reset to 0.
However, because cur_temp(57) < switch_on_temp(70)
last_temp(54) < switch_on_temp(70) ----> update = false,
update is false, the cooling device state can not be reset.
Using the observation that tz->passive can also be regarded as the
temperature status, set the update flag to the tz->passive value.
When the temperature drops below switch_on for the first time, the
states of cooling devices can be reset once, and tz->passive is updated
to 0. In the next round, because tz->passive is 0, cdev->state will not
be updated.
By using the tz->passive value as the "update" flag, the issue above
can be solved, and the cooling devices can be updated only once when the
temperature is low.
Fixes: 0952177f2a ("thermal/core/power_allocator: Update once cooling devices when temp is low")
Cc: 5.13+ <stable@vger.kernel.org> # 5.13+
Suggested-by: Wei Wang <wvw@google.com>
Signed-off-by: Di Shen <di.shen@unisoc.com>
Reviewed-by: Lukasz Luba <lukasz.luba@arm.com>
[ rjw: Subject and changelog edits ]
Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
Signed-off-by: Sasha Levin <sashal@kernel.org>
[ Upstream commit 2c7b4bfadef08cc0995c24a7b9eb120fe897165f ]
Replace the integer trip number stored in struct thermal_instance with
a pointer to the relevant trip and adjust the code using the structure
in question accordingly.
The main reason for making this change is to allow the trip point to
cooling device binding code more straightforward, as illustrated by
subsequent modifications of the ACPI thermal driver, but it also helps
to clarify the overall design and allows the governor code overhead to
be reduced (through subsequent modifications).
The only case in which it adds complexity is trip_point_show() that
needs to walk the trips[] table to find the index of the given trip
point, but this is not a critical path and the interface that
trip_point_show() belongs to is problematic anyway (for instance, it
doesn't cover the case when the same cooling devices is associated
with multiple trip points).
This is a preliminary change and the affected code will be refined by
a series of subsequent modifications of thermal governors, the core and
the ACPI thermal driver.
The general functionality is not expected to be affected by this change.
Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
Reviewed-by: Daniel Lezcano <daniel.lezcano@linaro.org>
Stable-dep-of: e95fa7404716 ("thermal: gov_power_allocator: avoid inability to reset a cdev")
Signed-off-by: Sasha Levin <sashal@kernel.org>
The traces are exported but only local to the thermal core code. On
the other side, the traces take the thermal zone device structure as
argument, thus they have to rely on the exported thermal.h header
file. As we want to move the structure to the private thermal core
header, first we have to relocate those traces to the same place as
many drivers do.
Cc: Steven Rostedt <rostedt@goodmis.org>
Suggested-by: Steven Rostedt <rostedt@goodmis.org>
Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
Reviewed-by: Steven Rostedt (Google) <rostedt@goodmis.org>
Link: https://lore.kernel.org/r/20230307133735.90772-2-daniel.lezcano@linaro.org
The governors are using the ops->get_trip_* functions, Replace these
calls with thermal_zone_get_trip().
Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
Reviewed-by: Zhang Rui <rui.zhang@intel.com>
Reviewed-by: Lukasz Luba <lukasz.luba@arm.com> # IPA
Acked-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
Link: https://lore.kernel.org/r/20221003092602.1323944-5-daniel.lezcano@linaro.org
All the governors throttling ops are taking/releasing the lock at the
beginning and the end of the function.
We can move the mutex to the throttling call site instead.
Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
Link: https://lore.kernel.org/r/20220805153834.2510142-4-daniel.lezcano@linaro.org
The thermal zone lock is taken in the different places in the
throttling path.
At the first glance it does not hurt to move them at the beginning and
the end of the 'throttle' function. That will allow a consolidation of
the lock in the next following changes.
Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
Link: https://lore.kernel.org/r/20220805153834.2510142-3-daniel.lezcano@linaro.org
In order to use thermal trips defined in the thermal structure, rename
the 'trips' field to 'num_trips' to have the 'trips' field containing the
thermal trip points.
Cc: Alexandre Bailon <abailon@baylibre.com>
Cc: Kevin Hilman <khilman@baylibre.com>
Signed-off-by: Daniel Lezcano <daniel.lezcano@linexp.org>
Link: https://lore.kernel.org/r/20220722200007.1839356-8-daniel.lezcano@linexp.org
Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
Use the new helper function and avoid unnecessery second lock/unlock,
which was present in old approach with thermal_cdev_update().
Signed-off-by: Lukasz Luba <lukasz.luba@arm.com>
Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
Link: https://lore.kernel.org/r/20210422153624.6074-4-lukasz.luba@arm.com
The cooling device state change generates an event, also when there is no
need, because temperature is low and device is not throttled. Avoid to
unnecessary update the cooling device which means also not sending event.
The cooling device state has not changed because the temperature is still
below the first activation trip point value, so we can do this.
Add a tracking mechanism to make sure it updates cooling devices only
once - when the temperature dropps below first trip point.
Reported-by: Daniel Lezcano <daniel.lezcano@linaro.org>
Signed-off-by: Lukasz Luba <lukasz.luba@arm.com>
Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
Link: https://lore.kernel.org/r/20210422114308.29684-4-lukasz.luba@arm.com
When the temperature is below the first activation trip point the cooling
devices are not checked, so they cannot maintain fresh statistics. It
leads into the situation, when temperature crosses first trip point, the
statistics are stale and show state for very long period. This has impact
on IPA algorithm calculation and wrong decisions. Thus, check the cooling
devices even when the temperature is low, to refresh these statistics.
Signed-off-by: Lukasz Luba <lukasz.luba@arm.com>
Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
Link: https://lore.kernel.org/r/20210422114308.29684-3-lukasz.luba@arm.com
The division is used directly in re-divvying up power, the decimal part will
be discarded, devices will get less than the extra_actor_power - 1.
if using round the division to make the calculation more accurate.
For example:
actor0 received more than its max_power, it has the extra_power 759
actor1 received less than its max_power, it require extra_actor_power 395
actor2 received less than its max_power, it require extra_actor_power 365
actor1 and actor2 require the total capped_extra_power 760
using division in re-divvying up power
actor1 would actually get the extra_actor_power 394
actor2 would actually get the extra_actor_power 364
if using round the division in re-divvying up power
actor1 would actually get the extra_actor_power 394
actor2 would actually get the extra_actor_power 365
Signed-off-by: Jeson Gao <jeson.gao@unisoc.com>
Reviewed-by: Lukasz Luba <lukasz.luba@arm.com>
Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
Link: https://lore.kernel.org/r/1615796737-4688-1-git-send-email-gao.yunxiao6@gmail.com
The thermal zone can have cooling devices which are missing power actor
API. This could be due to missing Energy Model for devfreq or cpufreq
cooling device. In this case it is safe to fail the binding rather than
trying to workaround and control the temperature in such thermal zone.
Signed-off-by: Lukasz Luba <lukasz.luba@arm.com>
Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
Link: https://lore.kernel.org/r/20210119114126.19480-1-lukasz.luba@arm.com
The code does no longer use the ms unit based fields to set the
delays as they are replaced by the jiffies.
Remove them and replace their user to use the jiffies version instead.
Cc: Thara Gopinath <thara.gopinath@linaro.org>
Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
Reviewed-by: Lukasz Luba <lukasz.luba@arm.com>
Reviewed-by: Peter Kästle <peter@piie.net>
Acked-by: Hans de Goede <hdegoede@redhat.com>
Link: https://lore.kernel.org/r/20201216220337.839878-3-daniel.lezcano@linaro.org
The PID coefficients should be estimated again when there was a change to
sustainable power value made by user. This change removes unused argument
'force' and makes the function ready for such updates.
Signed-off-by: Lukasz Luba <lukasz.luba@arm.com>
Reviewed-by: Ionela Voinescu <ionela.voinescu@arm.com>
Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
Link: https://lore.kernel.org/r/20201124161025.27694-4-lukasz.luba@arm.com
The sustainable power value might come from the Device Tree or can be
estimated in run time. The sustainable power might be updated by the user
via sysfs interface, which should trigger new estimation of PID
coefficients. There is no need to estimate it every time when the
governor is called and temperature is high. Instead, store the estimated
value and make it available via standard sysfs interface, so it can be
checked from the user-space.
Signed-off-by: Lukasz Luba <lukasz.luba@arm.com>
Reviewed-by: Ionela Voinescu <ionela.voinescu@arm.com>
Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
Link: https://lore.kernel.org/r/20201124161025.27694-3-lukasz.luba@arm.com
Intelligent Power Allocation (IPA) is built around the PID controller
concept. The initialization code tries to setup the environment based on
the information available in DT or estimate the value based on minimum
power reported by each of the cooling device. The estimation will have an
impact on the PID controller behaviour via the related 'k_po', 'k_pu',
'k_i' coefficients and also on the power budget calculation.
This change prevents the situation when 'k_i' is relatively big compared
to 'k_po' and 'k_pu' values. This might happen when the estimation for
'sustainable_power' returned small value, thus 'k_po' and 'k_pu' are
small.
Signed-off-by: Lukasz Luba <lukasz.luba@arm.com>
Reviewed-by: Ionela Voinescu <ionela.voinescu@arm.com>
Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
Link: https://lore.kernel.org/r/20201124161025.27694-2-lukasz.luba@arm.com
Since the power actor section has one function power_actor_set_power()
move it into Intelligent Power Allocation (IPA). There is no other user
of that helper function. It would also allow to remove the check of
cdev_is_power_actor() because the code which calls it in IPA already does
the needed check. Make the function static since only IPA use it.
Signed-off-by: Lukasz Luba <lukasz.luba@arm.com>
Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
Link: https://lore.kernel.org/r/20201015112441.4056-5-lukasz.luba@arm.com
The thermal cooling device specified in DT might be instantiated for
a thermal zone trip point with a limited set of OPPs to operate on. This
configuration should be supported by Intelligent Power Allocation (IPA),
since it is a standard for other governors. Change the code and allow IPA
to get power value of lower and upper bound set for a given cooling
device.
Signed-off-by: Lukasz Luba <lukasz.luba@arm.com>
Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
Link: https://lore.kernel.org/r/20201015112441.4056-3-lukasz.luba@arm.com
1. devfreq_cooling.c: The variable *tz is not used in
devfreq_cooling_get_requested_power(), devfreq_cooling_state2power()
and devfreq_cooling_power2state().
2. cpufreq_cooling.c: After 84fe2cab48, the variable *tz is not used
anymore in cpufreq_get_requested_power(), cpufreq_state2power() and
cpufreq_power2state().
Remove the variable *tz.
Signed-off-by: zhuguangqing <zhuguangqing@xiaomi.com>
Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
Link: https://lore.kernel.org/r/20200914071101.13575-1-zhuguangqing83@gmail.com