drm/panel: boe-tv101wum-nl6: Remove extra delay
Reduce the delay after LCM reset by removing an extra delay in the initialization commands array. The required delay of at least 6ms after reset is guaranteed by boe_panel_prepare(). Signed-off-by: Shuijing Li <shuijing.li@mediatek.com> Signed-off-by: Xinlei Lee <xinlei.lee@mediatek.com> Reviewed-by: AngeloGioacchino Del Regno <angelogioacchino.delregno@collabora.com> Signed-off-by: Neil Armstrong <neil.armstrong@linaro.org> Link: https://patchwork.freedesktop.org/patch/msgid/20230515094955.15982-2-shuijing.li@mediatek.com
This commit is contained in:
parent
0f1cb4d777
commit
fe7f4e8d49
|
@ -780,7 +780,6 @@ static const struct panel_init_cmd inx_hj110iz_init_cmd[] = {
|
|||
};
|
||||
|
||||
static const struct panel_init_cmd boe_init_cmd[] = {
|
||||
_INIT_DELAY_CMD(24),
|
||||
_INIT_DCS_CMD(0xB0, 0x05),
|
||||
_INIT_DCS_CMD(0xB1, 0xE5),
|
||||
_INIT_DCS_CMD(0xB3, 0x52),
|
||||
|
|
Loading…
Reference in New Issue