staging: comedi: pcl726: Use 16-bit 0 for interrupt data
The pcl726 driver has an "interrupt" subdevice that supports Comedi asynchronous commands, placing a value in the Comedi buffer for each interrupt. The subdevice uses Comedi's 16-bit sample format but the interrupt handler is calling `comedi_buf_write_samples()` with the address of a 32-bit integer `&s->state`. On bigendian machines, this will copy 2 bytes from the wrong end of the 32-bit integer. This isn't really a problem since `s->state` will always be 0 for this subdevice, but clean it up by using a 16-bit variable initialized to 0 to pass the value. Signed-off-by: Ian Abbott <abbotti@mev.co.uk> Link: https://lore.kernel.org/r/20210223143055.257402-15-abbotti@mev.co.uk Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
This commit is contained in:
parent
5ff1c08c28
commit
fd3ce6557d
|
@ -220,9 +220,11 @@ static irqreturn_t pcl726_interrupt(int irq, void *d)
|
|||
struct pcl726_private *devpriv = dev->private;
|
||||
|
||||
if (devpriv->cmd_running) {
|
||||
unsigned short val = 0;
|
||||
|
||||
pcl726_intr_cancel(dev, s);
|
||||
|
||||
comedi_buf_write_samples(s, &s->state, 1);
|
||||
comedi_buf_write_samples(s, &val, 1);
|
||||
comedi_handle_events(dev, s);
|
||||
}
|
||||
|
||||
|
|
Loading…
Reference in New Issue