Revert "s390/cpum_cf: Add kernel message exaplanations"
This reverts commit fb3a0b61e0
.
Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
This commit is contained in:
parent
9fe567d09f
commit
fcc082f35c
|
@ -1,36 +0,0 @@
|
|||
/*?
|
||||
* Text: "CPU[%i] Counter data was lost\n"
|
||||
* Severity: Error
|
||||
* Parameter:
|
||||
* @1: CPU identifier
|
||||
* Description:
|
||||
* The kernel could not extract data provided by the Performance Measurement Unit
|
||||
* (PMU) fast enough, some data is overwritten.
|
||||
* User action:
|
||||
* None
|
||||
*/
|
||||
|
||||
/*?
|
||||
* Text: "CPU[%i] MT counter data was lost\n"
|
||||
* Severity: Warning
|
||||
* Parameter:
|
||||
* @1: CPU identifier
|
||||
* Description:
|
||||
* The kernel could not extract data provided by the Performance Measurement Unit
|
||||
* (PMU) fast enough, some data is overwritten.
|
||||
* User action:
|
||||
* None
|
||||
*/
|
||||
|
||||
/*?
|
||||
* Text: "Registering for CPU-measurement alerts failed with rc=%i\n"
|
||||
* Severity: Error
|
||||
* Parameter:
|
||||
* @1: Return code of failed interrupt handler registration
|
||||
* Description:
|
||||
* Please insert description here
|
||||
* User action:
|
||||
* Reboot. If the problem persists, gather Linux debug data and report
|
||||
* the problem to your support organization.
|
||||
*/
|
||||
/*? Text: "%s: %d output lines suppressed due to ratelimiting\n" */
|
|
@ -1,45 +0,0 @@
|
|||
/*? Text: "%s: %d output lines suppressed due to ratelimiting\n" */
|
||||
/*? Text: "cpum_cf_diag counter set compare error in set %i\n" */
|
||||
/*? Text: "Registration of s390dbf(cpum_cf_diag) failed\n" */
|
||||
/*? Text: "Registration of PMU(cpum_cf_diag) failed with rc=%i\n" */
|
||||
|
||||
/*?
|
||||
* Text: "Enabling the performance measuring unit failed with rc=%x\n"
|
||||
* Severity: Error
|
||||
* Parameter:
|
||||
* @1: Error code returned by PMU enable function
|
||||
* Description:
|
||||
* The CPU Measurement Facilitiy for counters needs to be enabled to extract
|
||||
* counter data.
|
||||
* User action:
|
||||
* To use the CPU-measurement counter facility, authorize the LPAR for each
|
||||
* counter set you want to use. Customize the LPAR activation profile and modify
|
||||
* the Counter Facility Security Options. Then reboot.
|
||||
* If the problem persists, gather Linux debug data and report the
|
||||
* problem to your support organization.
|
||||
*/
|
||||
|
||||
/*?
|
||||
* Text: "Disabling the performance measuring unit failed with rc=%x\n"
|
||||
* Severity: Error
|
||||
* Parameter:
|
||||
* @1: Error code returned by PMU disable function
|
||||
* Description:
|
||||
* The CPU Measurement Facilitiy for counters is disabled to stop extraction
|
||||
* of counter data.
|
||||
* User action:
|
||||
* Reboot. If the problem persists, gather Linux debug data and report the
|
||||
* problem to your support organization.
|
||||
*/
|
||||
|
||||
/*?
|
||||
* Text: "Insufficient memory for PMU(cpum_cf_diag) need=%zu\n"
|
||||
* Severity: Error
|
||||
* Parameter:
|
||||
* @1: Required amount of bytes needed to store the counter sets.
|
||||
* Description:
|
||||
* The preallocted memory to store counter sets is too small.
|
||||
* User action:
|
||||
* If the problem persists, gather Linux debug data and report the
|
||||
* problem to your support organization.
|
||||
*/
|
Loading…
Reference in New Issue