smb347-charger: Clean up battery attributes
CURRENT_NOW and VOLTAGE_NOW should be instantaneous readings from power supply(ex: battery). smb347 charger driver reports charge voltage for VOLTAGE_NOW and charge current for CURRENT_NOW attributes which are not instantaneous readings. This patch removes the battery VOLTAGE_NOW and CURRENT_NOW properties from the driver and also removes hw_to_current() which is not required anymore. Signed-off-by: Ramakrishna Pallala <ramakrishna.pallala@intel.com> Acked-by: Mika Westerberg <mika.westerberg@linux.intel.com> Signed-off-by: Anton Vorontsov <anton.vorontsov@linaro.org>
This commit is contained in:
parent
9a8422d205
commit
fcc015cda7
|
@ -195,14 +195,6 @@ static const unsigned int ccc_tbl[] = {
|
|||
1200000,
|
||||
};
|
||||
|
||||
/* Convert register value to current using lookup table */
|
||||
static int hw_to_current(const unsigned int *tbl, size_t size, unsigned int val)
|
||||
{
|
||||
if (val >= size)
|
||||
return -EINVAL;
|
||||
return tbl[val];
|
||||
}
|
||||
|
||||
/* Convert current to register value using lookup table */
|
||||
static int current_to_hw(const unsigned int *tbl, size_t size, unsigned int val)
|
||||
{
|
||||
|
@ -891,7 +883,6 @@ static int smb347_battery_get_property(struct power_supply *psy,
|
|||
struct smb347_charger *smb =
|
||||
container_of(psy, struct smb347_charger, battery);
|
||||
const struct smb347_charger_platform_data *pdata = smb->pdata;
|
||||
unsigned int v;
|
||||
int ret;
|
||||
|
||||
ret = smb347_update_ps_status(smb);
|
||||
|
@ -943,44 +934,6 @@ static int smb347_battery_get_property(struct power_supply *psy,
|
|||
val->intval = pdata->battery_info.voltage_max_design;
|
||||
break;
|
||||
|
||||
case POWER_SUPPLY_PROP_VOLTAGE_NOW:
|
||||
if (!smb347_is_ps_online(smb))
|
||||
return -ENODATA;
|
||||
ret = regmap_read(smb->regmap, STAT_A, &v);
|
||||
if (ret < 0)
|
||||
return ret;
|
||||
|
||||
v &= STAT_A_FLOAT_VOLTAGE_MASK;
|
||||
if (v > 0x3d)
|
||||
v = 0x3d;
|
||||
|
||||
val->intval = 3500000 + v * 20000;
|
||||
break;
|
||||
|
||||
case POWER_SUPPLY_PROP_CURRENT_NOW:
|
||||
if (!smb347_is_ps_online(smb))
|
||||
return -ENODATA;
|
||||
|
||||
ret = regmap_read(smb->regmap, STAT_B, &v);
|
||||
if (ret < 0)
|
||||
return ret;
|
||||
|
||||
/*
|
||||
* The current value is composition of FCC and PCC values
|
||||
* and we can detect which table to use from bit 5.
|
||||
*/
|
||||
if (v & 0x20) {
|
||||
val->intval = hw_to_current(fcc_tbl,
|
||||
ARRAY_SIZE(fcc_tbl),
|
||||
v & 7);
|
||||
} else {
|
||||
v >>= 3;
|
||||
val->intval = hw_to_current(pcc_tbl,
|
||||
ARRAY_SIZE(pcc_tbl),
|
||||
v & 7);
|
||||
}
|
||||
break;
|
||||
|
||||
case POWER_SUPPLY_PROP_CHARGE_FULL_DESIGN:
|
||||
val->intval = pdata->battery_info.charge_full_design;
|
||||
break;
|
||||
|
@ -1002,8 +955,6 @@ static enum power_supply_property smb347_battery_properties[] = {
|
|||
POWER_SUPPLY_PROP_TECHNOLOGY,
|
||||
POWER_SUPPLY_PROP_VOLTAGE_MIN_DESIGN,
|
||||
POWER_SUPPLY_PROP_VOLTAGE_MAX_DESIGN,
|
||||
POWER_SUPPLY_PROP_VOLTAGE_NOW,
|
||||
POWER_SUPPLY_PROP_CURRENT_NOW,
|
||||
POWER_SUPPLY_PROP_CHARGE_FULL_DESIGN,
|
||||
POWER_SUPPLY_PROP_MODEL_NAME,
|
||||
};
|
||||
|
|
Loading…