s390/nospec: generate single register thunks if possible
Currently assembler generated expoline thunks are always in a form __s390_indirect_jump_rXuse_rX even when exrl instruction is available and no additional register is utilized. Generate __s390_indirect_jump_rX versions using a single register if the kernel is built for z10 or newer machine, which have exrl instruction available. Thunks generated are identical to the ones generated by the compiler. This helps to reduce the number of thunks for newer machines generations. Acked-by: Sumanth Korikkar <sumanthk@linux.ibm.com> Acked-by: Ilya Leoshkevich <iii@linux.ibm.com> Signed-off-by: Vasily Gorbik <gor@linux.ibm.com>
This commit is contained in:
parent
6c2797cd51
commit
eed38cd2f4
|
@ -31,6 +31,19 @@ _LC_BR_R1 = __LC_BR_R1
|
|||
.popsection
|
||||
.endm
|
||||
|
||||
#ifdef CONFIG_HAVE_MARCH_Z10_FEATURES
|
||||
.macro __THUNK_PROLOG_BR r1,r2
|
||||
__THUNK_PROLOG_NAME __s390_indirect_jump_r\r1
|
||||
.endm
|
||||
|
||||
.macro __THUNK_BR r1,r2
|
||||
jg __s390_indirect_jump_r\r1
|
||||
.endm
|
||||
|
||||
.macro __THUNK_BRASL r1,r2,r3
|
||||
brasl \r1,__s390_indirect_jump_r\r2
|
||||
.endm
|
||||
#else
|
||||
.macro __THUNK_PROLOG_BR r1,r2
|
||||
__THUNK_PROLOG_NAME __s390_indirect_jump_r\r2\()use_r\r1
|
||||
.endm
|
||||
|
@ -42,6 +55,7 @@ _LC_BR_R1 = __LC_BR_R1
|
|||
.macro __THUNK_BRASL r1,r2,r3
|
||||
brasl \r1,__s390_indirect_jump_r\r3\()use_r\r2
|
||||
.endm
|
||||
#endif
|
||||
|
||||
.macro __DECODE_RR expand,reg,ruse
|
||||
.set __decode_fail,1
|
||||
|
|