iio: Correct description how to convert microtesla to gauss
this just fixes the comment; however, I'm not sure if the driver reports measurements correctly; the raw values are 0.3 uT / LSB; IIO is supposed to report magnetic fields in Gauss, so the scale should be around 1/300 (ignoring ASA) -- but value and scale are returned as VAL_INT Signed-off-by: Peter Meerwald <pmeerw@pmeerw.net> Signed-off-by: Jonathan Cameron <jic23@kernel.org>
This commit is contained in:
parent
207287595b
commit
eb03610a9c
|
@ -263,7 +263,7 @@ static int ak8975_setup(struct i2c_client *client)
|
|||
*
|
||||
* HuT = H * 1229/4096, or roughly, 3/10.
|
||||
*
|
||||
* Since 1uT = 100 gauss, our final scale factor becomes:
|
||||
* Since 1uT = 0.01 gauss, our final scale factor becomes:
|
||||
*
|
||||
* Hadj = H * ((ASA + 128) / 256) * 3/10 * 100
|
||||
* Hadj = H * ((ASA + 128) * 30 / 256
|
||||
|
|