hwrng: core - Fix wrong quality calculation at hw rng registration

[ Upstream commit 95c0f5c3b8bb7acdc5c4f04bc6a7d3f40d319e9e ]

When there are rng sources registering at the hwrng core via
hwrng_register() a struct hwrng is delivered. There is a quality
field in there which is used to decide which of the registered
hw rng sources will be used by the hwrng core.

With commit 16bdbae394 ("hwrng: core - treat default_quality as
a maximum and default to 1024") there came in a new default of
1024 in case this field is empty and all the known hw rng sources
at that time had been reworked to not fill this field and thus
use the default of 1024.

The code choosing the 'better' hw rng source during registration
of a new hw rng source has never been adapted to this and thus
used 0 if the hw rng implementation does not fill the quality field.
So when two rng sources register, one with 0 (meaning 1024) and
the other one with 999, the 999 hw rng will be chosen.

As the later invoked function hwrng_init() anyway adjusts the
quality field of the hw rng source, this adjustment is now done
during registration of this new hw rng source.

Tested on s390 with two hardware rng sources: crypto cards and
trng true random generator device driver.

Fixes: 16bdbae394 ("hwrng: core - treat default_quality as a maximum and default to 1024")
Reported-by: Christian Rund <Christian.Rund@de.ibm.com>
Suggested-by: Herbert Xu <herbert@gondor.apana.org.au>
Signed-off-by: Harald Freudenberger <freude@linux.ibm.com>
Signed-off-by: Herbert Xu <herbert@gondor.apana.org.au>
Signed-off-by: Sasha Levin <sashal@kernel.org>
This commit is contained in:
Harald Freudenberger 2024-06-21 17:02:24 +02:00 committed by Greg Kroah-Hartman
parent 57600a7dd2
commit e977bf4c61
1 changed files with 3 additions and 1 deletions

View File

@ -174,7 +174,6 @@ static int hwrng_init(struct hwrng *rng)
reinit_completion(&rng->cleanup_done);
skip_init:
rng->quality = min_t(u16, min_t(u16, default_quality, 1024), rng->quality ?: 1024);
current_quality = rng->quality; /* obsolete */
return 0;
@ -563,6 +562,9 @@ int hwrng_register(struct hwrng *rng)
complete(&rng->cleanup_done);
init_completion(&rng->dying);
/* Adjust quality field to always have a proper value */
rng->quality = min_t(u16, min_t(u16, default_quality, 1024), rng->quality ?: 1024);
if (!current_rng ||
(!cur_rng_set_by_user && rng->quality > current_rng->quality)) {
/*