dt-bindings: mfd: DA9062/61 MFD binding

Extend existing DA9062 binding information to include the DA9061 PMIC for
MFD core and regulators.

Add a da9062-onkey link to the existing onkey binding file.

Add a da9062-thermal link to the new temperature monitoring binding file.

Delete the da9062-watchdog section and replace it with a link to the new
DA9061/62 binding information file.

Acked-by: Rob Herring <robh@kernel.org>
Signed-off-by: Steve Twiss <stwiss.opensource@diasemi.com>
Signed-off-by: Lee Jones <lee.jones@linaro.org>
This commit is contained in:
Steve Twiss 2017-03-28 15:43:31 +01:00 committed by Lee Jones
parent b97eef5d77
commit e1569fb64e
1 changed files with 36 additions and 13 deletions

View File

@ -1,22 +1,39 @@
* Dialog DA9062 Power Management Integrated Circuit (PMIC)
DA9062 consists of a large and varied group of sub-devices:
Product information for the DA9062 and DA9061 devices can be found here:
- http://www.dialog-semiconductor.com/products/da9062
- http://www.dialog-semiconductor.com/products/da9061
The DA9062 PMIC consists of:
Device Supply Names Description
------ ------------ -----------
da9062-regulator : : LDOs & BUCKs
da9062-rtc : : Real-Time Clock
da9062-onkey : : On Key
da9062-watchdog : : Watchdog Timer
da9062-thermal : : Thermal
The DA9061 PMIC consists of:
Device Supply Names Description
------ ------------ -----------
da9062-regulator : : LDOs & BUCKs
da9062-onkey : : On Key
da9062-watchdog : : Watchdog Timer
da9062-thermal : : Thermal
======
Required properties:
- compatible : Should be "dlg,da9062".
- compatible : Should be
"dlg,da9062" for DA9062
"dlg,da9061" for DA9061
- reg : Specifies the I2C slave address (this defaults to 0x58 but it can be
modified to match the chip's OTP settings).
- interrupt-parent : Specifies the reference to the interrupt controller for
the DA9062.
the DA9062 or DA9061.
- interrupts : IRQ line information.
- interrupt-controller
@ -25,8 +42,8 @@ further information on IRQ bindings.
Sub-nodes:
- regulators : This node defines the settings for the LDOs and BUCKs. The
DA9062 regulators are bound using their names listed below:
- regulators : This node defines the settings for the LDOs and BUCKs.
The DA9062 regulators are bound using their names listed below:
buck1 : BUCK_1
buck2 : BUCK_2
@ -37,19 +54,29 @@ Sub-nodes:
ldo3 : LDO_3
ldo4 : LDO_4
The DA9061 regulators are bound using their names listed below:
buck1 : BUCK_1
buck2 : BUCK_2
buck3 : BUCK_3
ldo1 : LDO_1
ldo2 : LDO_2
ldo3 : LDO_3
ldo4 : LDO_4
The component follows the standard regulator framework and the bindings
details of individual regulator device can be found in:
Documentation/devicetree/bindings/regulator/regulator.txt
- rtc : This node defines settings required for the Real-Time Clock associated
with the DA9062. There are currently no entries in this binding, however
compatible = "dlg,da9062-rtc" should be added if a node is created.
- watchdog: This node defines the settings for the watchdog driver associated
with the DA9062 PMIC. The compatible = "dlg,da9062-watchdog" should be added
if a node is created.
- onkey : See ../input/da9062-onkey.txt
- watchdog: See ../watchdog/da9062-watchdog.txt
- thermal : See ../thermal/da9062-thermal.txt
Example:
@ -64,10 +91,6 @@ Example:
compatible = "dlg,da9062-rtc";
};
watchdog {
compatible = "dlg,da9062-watchdog";
};
regulators {
DA9062_BUCK1: buck1 {
regulator-name = "BUCK1";