drm/amd/pm: reverse mclk clocks levels for SMU v13.0.5
This patch reverses the DPM clocks levels output of pp_dpm_mclk. On dGPUs and older APUs we expose the levels from lowest clocks to highest clocks. But for some APUs, the clocks levels that from the DFPstateTable are given the reversed orders by PMFW. Like the memory DPM clocks that are exposed by pp_dpm_mclk. It's not intuitive that they are reversed on these APUs. All tools and software that talks to the driver then has to know different ways to interpret the data depending on the asic. So we need to reverse them to expose the clocks levels from the driver consistently. Signed-off-by: Tim Huang <Tim.Huang@amd.com> Reviewed-by: Alex Deucher <alexander.deucher@amd.com> Signed-off-by: Alex Deucher <alexander.deucher@amd.com>
This commit is contained in:
parent
665d49c27e
commit
d9ed111b76
|
@ -866,7 +866,7 @@ out:
|
|||
static int smu_v13_0_5_print_clk_levels(struct smu_context *smu,
|
||||
enum smu_clk_type clk_type, char *buf)
|
||||
{
|
||||
int i, size = 0, ret = 0;
|
||||
int i, idx, size = 0, ret = 0;
|
||||
uint32_t cur_value = 0, value = 0, count = 0;
|
||||
uint32_t min = 0, max = 0;
|
||||
|
||||
|
@ -898,7 +898,8 @@ static int smu_v13_0_5_print_clk_levels(struct smu_context *smu,
|
|||
goto print_clk_out;
|
||||
|
||||
for (i = 0; i < count; i++) {
|
||||
ret = smu_v13_0_5_get_dpm_freq_by_index(smu, clk_type, i, &value);
|
||||
idx = (clk_type == SMU_MCLK) ? (count - i - 1) : i;
|
||||
ret = smu_v13_0_5_get_dpm_freq_by_index(smu, clk_type, idx, &value);
|
||||
if (ret)
|
||||
goto print_clk_out;
|
||||
|
||||
|
|
Loading…