ASoC: samsung: Don't clear clock setting during i2s_startup
In exiting kernel, if DAIFMT flags are set in dai_link and I2S is set to run in master mode, the I2S clocks are not getting configured resulting in no output. Existing code clears the current I2S clock settings during i2s_startup and requires that the clocks are reconfigured. It then assumes that sound-card driver would call snd_soc_dai_{set_sysclk/set_fmt} to configure the root clock. 1. Since I2S clock settings remain fixed for a board, it would be better to set the clocks once during sound-card probe. 2. Also if the DAIFMT flags are set in dai_link, snd_soc_dai_set_fmt is called during DAI probe. If both these conditions are true, then I2S clock remains unconfigured during audio playback. Fix this by removing the code to clear rclk_srcrate in i2s_startup. Instead, reset this during DAI probe. Signed-off-by: Tushar Behera <tushar.behera@linaro.org> Signed-off-by: Mark Brown <broonie@linaro.org>
This commit is contained in:
parent
c9eaa447e7
commit
d66eac3e2b
|
@ -724,9 +724,6 @@ static int i2s_startup(struct snd_pcm_substream *substream,
|
|||
else
|
||||
i2s->mode |= DAI_MANAGER;
|
||||
|
||||
/* Enforce set_sysclk in Master mode */
|
||||
i2s->rclk_srcrate = 0;
|
||||
|
||||
if (!any_active(i2s) && (i2s->quirks & QUIRK_NEED_RSTCLR))
|
||||
writel(CON_RSTCLR, i2s->addr + I2SCON);
|
||||
|
||||
|
@ -984,6 +981,7 @@ probe_exit:
|
|||
/* Reset any constraint on RFS and BFS */
|
||||
i2s->rfs = 0;
|
||||
i2s->bfs = 0;
|
||||
i2s->rclk_srcrate = 0;
|
||||
i2s_txctrl(i2s, 0);
|
||||
i2s_rxctrl(i2s, 0);
|
||||
i2s_fifo(i2s, FIC_TXFLUSH);
|
||||
|
|
Loading…
Reference in New Issue