ASoC: tlv320dac33: Limit the US_TO_SAMPLES macro
Limit the time window to maximum 1s in the macro. The driver deals with much shorter times (<200ms). This will fix a rare division by zero bug in Mode1. This could happen, when the work is not executed in time (within mode1_latency) after the interrupt. In this case the DAC33 will not receive the needed nSample command in time, and enters to an unknown state, and won't recover. In such event the time window will increase, and eventually going to be bigger than 1s, resulting devision by zero. Signed-off-by: Peter Ujfalusi <peter.ujfalusi@nokia.com> Acked-by: Mark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: Liam Girdwood <lrg@slimlogic.co.uk>
This commit is contained in:
parent
911a0f0bfc
commit
d54e1f4fdf
|
@ -58,7 +58,7 @@
|
|||
(1000000000 / ((rate * 1000) / samples))
|
||||
|
||||
#define US_TO_SAMPLES(rate, us) \
|
||||
(rate / (1000000 / us))
|
||||
(rate / (1000000 / (us < 1000000 ? us : 1000000)))
|
||||
|
||||
#define UTHR_FROM_PERIOD_SIZE(samples, playrate, burstrate) \
|
||||
((samples * 5000) / ((burstrate * 5000) / (burstrate - playrate)))
|
||||
|
|
Loading…
Reference in New Issue