iio: adc: vf610_adc: Fix VALT selection value for REFSEL bits
In order to select the alternate voltage reference pair (VALTH/VALTL), the
right value for the REFSEL field in the ADCx_CFG register is "01", leading
to 0x800 as register mask. See section 8.2.6.4 in the reference manual[1].
[1] http://www.nxp.com/docs/en/reference-manual/VFXXXRM.pdf
Fixes: a775427632
("iio:adc:imx: add Freescale Vybrid vf610 adc driver")
Signed-off-by: Stefan-Gabriel Mirea <stefan-gabriel.mirea@nxp.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
This commit is contained in:
parent
a7b8829d24
commit
d466d3c121
|
@ -77,7 +77,7 @@
|
|||
#define VF610_ADC_ADSTS_MASK 0x300
|
||||
#define VF610_ADC_ADLPC_EN 0x80
|
||||
#define VF610_ADC_ADHSC_EN 0x400
|
||||
#define VF610_ADC_REFSEL_VALT 0x100
|
||||
#define VF610_ADC_REFSEL_VALT 0x800
|
||||
#define VF610_ADC_REFSEL_VBG 0x1000
|
||||
#define VF610_ADC_ADTRG_HARD 0x2000
|
||||
#define VF610_ADC_AVGS_8 0x4000
|
||||
|
|