net: pcs: xpcs: Fix a less than zero u16 comparison error

Currently the check for the u16 variable val being less than zero is
always false because val is unsigned. Fix this by using the int
variable for the assignment and less than zero check.

Addresses-Coverity: ("Unsigned compared against 0")
Fixes: f7380bba42 ("net: pcs: xpcs: add support for NXP SJA1110")
Signed-off-by: Colin Ian King <colin.king@canonical.com>
Reviewed-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
This commit is contained in:
Colin Ian King 2021-06-15 14:52:53 +01:00 committed by David S. Miller
parent 0c33795231
commit d356dbe23f
1 changed files with 6 additions and 6 deletions

View File

@ -152,13 +152,13 @@ static int nxp_sja1110_pma_config(struct dw_xpcs *xpcs,
/* Enable TX and RX PLLs and circuits.
* Release reset of PMA to enable data flow to/from PCS.
*/
val = xpcs_read(xpcs, MDIO_MMD_VEND2, SJA1110_POWERDOWN_ENABLE);
if (val < 0)
return val;
ret = xpcs_read(xpcs, MDIO_MMD_VEND2, SJA1110_POWERDOWN_ENABLE);
if (ret < 0)
return ret;
val &= ~(SJA1110_TXPLL_PD | SJA1110_TXPD | SJA1110_RXCH_PD |
SJA1110_RXBIAS_PD | SJA1110_RESET_SER_EN |
SJA1110_RESET_SER | SJA1110_RESET_DES);
val = ret & ~(SJA1110_TXPLL_PD | SJA1110_TXPD | SJA1110_RXCH_PD |
SJA1110_RXBIAS_PD | SJA1110_RESET_SER_EN |
SJA1110_RESET_SER | SJA1110_RESET_DES);
val |= SJA1110_RXPKDETEN | SJA1110_RCVEN;
ret = xpcs_write(xpcs, MDIO_MMD_VEND2, SJA1110_POWERDOWN_ENABLE, val);