regulator: Allow boot_on regulators to be disabled by clients
Rather than incrementing the reference count for boot_on regulators (which prevents them being disabled later on) simply force the regulator to be enabled when applying the constraints. Previously boot_on was essentially equivalent to always_on. Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: Liam Girdwood <lrg@slimlogic.co.uk>
This commit is contained in:
parent
221a7c7c9c
commit
cacf90f24e
|
@ -776,10 +776,6 @@ static int set_machine_constraints(struct regulator_dev *rdev,
|
|||
}
|
||||
}
|
||||
|
||||
/* are we enabled at boot time by firmware / bootloader */
|
||||
if (rdev->constraints->boot_on)
|
||||
rdev->use_count = 1;
|
||||
|
||||
/* do we need to setup our suspend state */
|
||||
if (constraints->initial_state) {
|
||||
ret = suspend_prepare(rdev, constraints->initial_state);
|
||||
|
@ -808,11 +804,10 @@ static int set_machine_constraints(struct regulator_dev *rdev,
|
|||
}
|
||||
}
|
||||
|
||||
/* if always_on is set then turn the regulator on if it's not
|
||||
* already on. */
|
||||
if (constraints->always_on && ops->enable &&
|
||||
((ops->is_enabled && !ops->is_enabled(rdev)) ||
|
||||
(!ops->is_enabled && !constraints->boot_on))) {
|
||||
/* If the constraints say the regulator should be on at this point
|
||||
* and we have control then make sure it is enabled.
|
||||
*/
|
||||
if ((constraints->always_on || constraints->boot_on) && ops->enable) {
|
||||
ret = ops->enable(rdev);
|
||||
if (ret < 0) {
|
||||
printk(KERN_ERR "%s: failed to enable %s\n",
|
||||
|
|
|
@ -73,7 +73,9 @@ struct regulator_state {
|
|||
*
|
||||
* @always_on: Set if the regulator should never be disabled.
|
||||
* @boot_on: Set if the regulator is enabled when the system is initially
|
||||
* started.
|
||||
* started. If the regulator is not enabled by the hardware or
|
||||
* bootloader then it will be enabled when the constraints are
|
||||
* applied.
|
||||
* @apply_uV: Apply the voltage constraint when initialising.
|
||||
*
|
||||
* @input_uV: Input voltage for regulator when supplied by another regulator.
|
||||
|
|
Loading…