ARM: OMAP3: clock data: treat all AM35x devices the same
The init for 3505/3517 specific clocks depends on the ordering of cpu_is checks, is error prone and confusing (there are 2 separate checks for cpu_is_omap3505()). Remove the 3505-specific checking since CK_3505 flag is not used, and treat all AM35x clocks the same. This means that the SGX clock (the only AM35x clkdev not currently flagged for 3505) will now be registered on 3505, but that is harmless. That can be cleaned up when the clkdev nodes are removed in favor of them being registered by hwmod. Acked-by: Vaibhav Hiremath <hvaibhav@ti.com> Tested-by: Vaibhav Hiremath <hvaibhav@ti.com> Signed-off-by: Kevin Hilman <khilman@ti.com> Signed-off-by: Paul Walmsley <paul@pwsan.com>
This commit is contained in:
parent
875e6897e0
commit
c93a98c902
|
@ -3513,21 +3513,9 @@ int __init omap3xxx_clk_init(void)
|
|||
struct omap_clk *c;
|
||||
u32 cpu_clkflg = 0;
|
||||
|
||||
/*
|
||||
* 3505 must be tested before 3517, since 3517 returns true
|
||||
* for both AM3517 chips and AM3517 family chips, which
|
||||
* includes 3505. Unfortunately there's no obvious family
|
||||
* test for 3517/3505 :-(
|
||||
*/
|
||||
if (cpu_is_omap3505()) {
|
||||
cpu_mask = RATE_IN_34XX;
|
||||
cpu_clkflg = CK_3505;
|
||||
} else if (cpu_is_omap3517()) {
|
||||
if (cpu_is_omap3517()) {
|
||||
cpu_mask = RATE_IN_34XX;
|
||||
cpu_clkflg = CK_3517;
|
||||
} else if (cpu_is_omap3505()) {
|
||||
cpu_mask = RATE_IN_34XX;
|
||||
cpu_clkflg = CK_3505;
|
||||
} else if (cpu_is_omap3630()) {
|
||||
cpu_mask = (RATE_IN_34XX | RATE_IN_36XX);
|
||||
cpu_clkflg = CK_36XX;
|
||||
|
|
Loading…