RDMA/nes: Update refcnt during disconnect

During termination, it is possible for the refcnt to go to zero while
the worker thread is posting events upward.  This fix increments the
refcnt before the request is passed to the worker thread.  The thread
decrements the refcnt when the request is completed.

Signed-off-by: Don Wood <donald.e.wood@intel.com>
Signed-off-by: Roland Dreier <rolandd@cisco.com>
This commit is contained in:
Don Wood 2009-09-05 20:36:36 -07:00 committed by Roland Dreier
parent e07cccf404
commit c4c3f279cd
1 changed files with 2 additions and 0 deletions

View File

@ -2456,6 +2456,7 @@ int nes_cm_disconn(struct nes_qp *nesqp)
if (nesqp->disconn_pending == 0) {
nesqp->disconn_pending++;
spin_unlock_irqrestore(&nesqp->lock, flags);
nes_add_ref(&nesqp->ibqp);
/* init our disconnect work element, to */
INIT_WORK(&nesqp->disconn_work, nes_disconnect_worker);
@ -2477,6 +2478,7 @@ static void nes_disconnect_worker(struct work_struct *work)
nes_debug(NES_DBG_CM, "processing AEQE id 0x%04X for QP%u.\n",
nesqp->last_aeq, nesqp->hwqp.qp_id);
nes_cm_disconn_true(nesqp);
nes_rem_ref(&nesqp->ibqp);
}