dt-bindings: thermal: Add yaml bindings for thermal sensors
As part of moving the thermal bindings to YAML, split it up into 3 bindings: thermal sensors, cooling devices and thermal zones. The property #thermal-sensor-cells is required in each device that acts as a thermal sensor. It is used to uniquely identify the instance of the thermal sensor inside the system. Signed-off-by: Amit Kucheria <amit.kucheria@linaro.org> Reviewed-by: Rob Herring <robh@kernel.org> Reviewed-by: Lukasz Luba <lukasz.luba@arm.com> Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org> Link: https://lore.kernel.org/r/a91b5603caea5b8854cc9f5325448e4c7228c328.1585748882.git.amit.kucheria@linaro.org
This commit is contained in:
parent
fc7a3d9e9c
commit
c1bba2c94d
|
@ -0,0 +1,72 @@
|
||||||
|
# SPDX-License-Identifier: (GPL-2.0)
|
||||||
|
# Copyright 2020 Linaro Ltd.
|
||||||
|
%YAML 1.2
|
||||||
|
---
|
||||||
|
$id: http://devicetree.org/schemas/thermal/thermal-sensor.yaml#
|
||||||
|
$schema: http://devicetree.org/meta-schemas/core.yaml#
|
||||||
|
|
||||||
|
title: Thermal sensor binding
|
||||||
|
|
||||||
|
maintainers:
|
||||||
|
- Amit Kucheria <amitk@kernel.org>
|
||||||
|
|
||||||
|
description: |
|
||||||
|
Thermal management is achieved in devicetree by describing the sensor hardware
|
||||||
|
and the software abstraction of thermal zones required to take appropriate
|
||||||
|
action to mitigate thermal overloads.
|
||||||
|
|
||||||
|
The following node types are used to completely describe a thermal management
|
||||||
|
system in devicetree:
|
||||||
|
- thermal-sensor: device that measures temperature, has SoC-specific bindings
|
||||||
|
- cooling-device: device used to dissipate heat either passively or actively
|
||||||
|
- thermal-zones: a container of the following node types used to describe all
|
||||||
|
thermal data for the platform
|
||||||
|
|
||||||
|
This binding describes the thermal-sensor.
|
||||||
|
|
||||||
|
Thermal sensor devices provide temperature sensing capabilities on thermal
|
||||||
|
zones. Typical devices are I2C ADC converters and bandgaps. Thermal sensor
|
||||||
|
devices may control one or more internal sensors.
|
||||||
|
|
||||||
|
properties:
|
||||||
|
"#thermal-sensor-cells":
|
||||||
|
description:
|
||||||
|
Used to uniquely identify a thermal sensor instance within an IC. Will be
|
||||||
|
0 on sensor nodes with only a single sensor and at least 1 on nodes
|
||||||
|
containing several internal sensors.
|
||||||
|
enum: [0, 1]
|
||||||
|
|
||||||
|
examples:
|
||||||
|
- |
|
||||||
|
#include <dt-bindings/interrupt-controller/arm-gic.h>
|
||||||
|
|
||||||
|
// Example 1: SDM845 TSENS
|
||||||
|
soc: soc@0 {
|
||||||
|
#address-cells = <2>;
|
||||||
|
#size-cells = <2>;
|
||||||
|
|
||||||
|
/* ... */
|
||||||
|
|
||||||
|
tsens0: thermal-sensor@c263000 {
|
||||||
|
compatible = "qcom,sdm845-tsens", "qcom,tsens-v2";
|
||||||
|
reg = <0 0x0c263000 0 0x1ff>, /* TM */
|
||||||
|
<0 0x0c222000 0 0x1ff>; /* SROT */
|
||||||
|
#qcom,sensors = <13>;
|
||||||
|
interrupts = <GIC_SPI 506 IRQ_TYPE_LEVEL_HIGH>,
|
||||||
|
<GIC_SPI 508 IRQ_TYPE_LEVEL_HIGH>;
|
||||||
|
interrupt-names = "uplow", "critical";
|
||||||
|
#thermal-sensor-cells = <1>;
|
||||||
|
};
|
||||||
|
|
||||||
|
tsens1: thermal-sensor@c265000 {
|
||||||
|
compatible = "qcom,sdm845-tsens", "qcom,tsens-v2";
|
||||||
|
reg = <0 0x0c265000 0 0x1ff>, /* TM */
|
||||||
|
<0 0x0c223000 0 0x1ff>; /* SROT */
|
||||||
|
#qcom,sensors = <8>;
|
||||||
|
interrupts = <GIC_SPI 507 IRQ_TYPE_LEVEL_HIGH>,
|
||||||
|
<GIC_SPI 509 IRQ_TYPE_LEVEL_HIGH>;
|
||||||
|
interrupt-names = "uplow", "critical";
|
||||||
|
#thermal-sensor-cells = <1>;
|
||||||
|
};
|
||||||
|
};
|
||||||
|
...
|