Input: edt-ft5x06 - adjust delays to conform datasheet
The FT5x06 datasheet specifies a minimum reset width of 5ms and a delay between deassertion of reset and start of reporting of 300ms. Adjust the delays to conform to the datasheet. With the original delays I sometimes experienced communication timeouts when initializing the controller. Signed-off-by: Lothar Waßmann <LW@KARO-electronics.de> Acked-by: Fugang Duan <B38611@freescale.com> Signed-off-by: Dmitry Torokhov <dmitry.torokhov@gmail.com>
This commit is contained in:
parent
dac90dc232
commit
c080846749
|
@ -635,7 +635,7 @@ static int edt_ft5x06_ts_reset(struct i2c_client *client,
|
|||
return error;
|
||||
}
|
||||
|
||||
mdelay(5);
|
||||
msleep(5);
|
||||
gpio_set_value(tsdata->wake_pin, 1);
|
||||
}
|
||||
if (gpio_is_valid(tsdata->reset_pin)) {
|
||||
|
@ -650,9 +650,9 @@ static int edt_ft5x06_ts_reset(struct i2c_client *client,
|
|||
return error;
|
||||
}
|
||||
|
||||
mdelay(50);
|
||||
msleep(5);
|
||||
gpio_set_value(tsdata->reset_pin, 1);
|
||||
mdelay(100);
|
||||
msleep(300);
|
||||
}
|
||||
|
||||
return 0;
|
||||
|
|