thermal/drivers/hisi: Convert long to int
There is no point to specify the temperature as long variable, the int is enough. Replace all long variables to int, so making the code consistent. Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org> Reviewed-by: Leo Yan <leo.yan@linaro.org> Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
This commit is contained in:
parent
609f26dcbb
commit
bc02ef6d98
|
@ -85,12 +85,12 @@ static inline int hisi_thermal_step_to_temp(int step)
|
|||
return HISI_TEMP_BASE + (step * HISI_TEMP_STEP);
|
||||
}
|
||||
|
||||
static inline long hisi_thermal_temp_to_step(long temp)
|
||||
static inline int hisi_thermal_temp_to_step(int temp)
|
||||
{
|
||||
return (temp - HISI_TEMP_BASE) / HISI_TEMP_STEP;
|
||||
}
|
||||
|
||||
static inline long hisi_thermal_round_temp(int temp)
|
||||
static inline int hisi_thermal_round_temp(int temp)
|
||||
{
|
||||
return hisi_thermal_step_to_temp(
|
||||
hisi_thermal_temp_to_step(temp));
|
||||
|
|