regulator: cleanup comments
For spdx Remove leading space, add space after // Replacements overriden to overridden Calulate to Calculate addional to additional regulatior to regulator devive to device Signed-off-by: Tom Rix <trix@redhat.com> Acked-by: Charles Keepax <ckeepax@opensource.cirrus.com> Link: https://lore.kernel.org/r/20220305162438.689442-1-trix@redhat.com Signed-off-by: Mark Brown <broonie@kernel.org>
This commit is contained in:
parent
80c056656d
commit
bbc7ba0fa0
|
@ -459,7 +459,7 @@ static int max8973_thermal_read_temp(void *data, int *temp)
|
|||
return ret;
|
||||
}
|
||||
|
||||
/* +1 degC to trigger cool devive */
|
||||
/* +1 degC to trigger cool device */
|
||||
if (val & MAX77621_CHIPID_TJINT_S)
|
||||
*temp = mchip->junction_temp_warning + 1000;
|
||||
else
|
||||
|
|
|
@ -1,4 +1,4 @@
|
|||
//SPDX-License-Identifier: GPL-2.0
|
||||
// SPDX-License-Identifier: GPL-2.0
|
||||
/*
|
||||
* Copyright (C) 2017 Spreadtrum Communications Inc.
|
||||
*/
|
||||
|
|
|
@ -42,7 +42,7 @@
|
|||
/**
|
||||
* struct ti_abb_info - ABB information per voltage setting
|
||||
* @opp_sel: one of TI_ABB macro
|
||||
* @vset: (optional) vset value that LDOVBB needs to be overriden with.
|
||||
* @vset: (optional) vset value that LDOVBB needs to be overridden with.
|
||||
*
|
||||
* Array of per voltage entries organized in the same order as regulator_desc's
|
||||
* volt_table list. (selector is used to index from this array)
|
||||
|
@ -484,7 +484,7 @@ static int ti_abb_init_timings(struct device *dev, struct ti_abb *abb)
|
|||
/* Calculate cycle rate */
|
||||
cycle_rate = DIV_ROUND_CLOSEST(clock_cycles * 10, clk_rate);
|
||||
|
||||
/* Calulate SR2_WTCNT_VALUE */
|
||||
/* Calculate SR2_WTCNT_VALUE */
|
||||
sr2_wt_cnt_val = DIV_ROUND_CLOSEST(abb->settling_time * 10, cycle_rate);
|
||||
|
||||
dev_dbg(dev, "%s: Clk_rate=%ld, sr2_cnt=0x%08x\n", __func__,
|
||||
|
@ -688,7 +688,7 @@ MODULE_DEVICE_TABLE(of, ti_abb_of_match);
|
|||
* @pdev: ABB platform device
|
||||
*
|
||||
* Initializes an individual ABB LDO for required Body-Bias. ABB is used to
|
||||
* addional bias supply to SoC modules for power savings or mandatory stability
|
||||
* additional bias supply to SoC modules for power savings or mandatory stability
|
||||
* configuration at certain Operating Performance Points(OPPs).
|
||||
*
|
||||
* Return: 0 on success or appropriate error value when fails
|
||||
|
|
|
@ -1112,7 +1112,7 @@ static int wm8350_regulator_probe(struct platform_device *pdev)
|
|||
if (pdev->id < WM8350_DCDC_1 || pdev->id > WM8350_ISINK_B)
|
||||
return -ENODEV;
|
||||
|
||||
/* do any regulatior specific init */
|
||||
/* do any regulator specific init */
|
||||
switch (pdev->id) {
|
||||
case WM8350_DCDC_1:
|
||||
val = wm8350_reg_read(wm8350, WM8350_DCDC1_LOW_POWER);
|
||||
|
|