power: supply: cpcap-battery: Use charger status for battery full detection
We now get battery full notification from cpcap-charger, so let's use that for battery full status and charger disconnect. Note that any current based battery full detection we have tried earlier is flakey as it won't account for example for CPU load increasing the battery current. Anyways, if current based battery full detection is also still needed, we can reconsider adding it in addition to the charger status based detection. Cc: Arthur Demchenkov <spinal.by@gmail.com> Cc: Carl Philipp Klemm <philipp@uvos.xyz> Cc: Merlijn Wajer <merlijn@wizzup.org> Cc: Pavel Machek <pavel@ucw.cz> Signed-off-by: Tony Lindgren <tony@atomide.com> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
This commit is contained in:
parent
2071236b85
commit
bb8b9a9850
|
@ -135,6 +135,7 @@ struct cpcap_battery_ddata {
|
|||
atomic_t active;
|
||||
int status;
|
||||
u16 vendor;
|
||||
unsigned int is_full:1;
|
||||
};
|
||||
|
||||
#define CPCAP_NO_BATTERY -400
|
||||
|
@ -371,15 +372,62 @@ static int cpcap_battery_cc_get_avg_current(struct cpcap_battery_ddata *ddata)
|
|||
return cpcap_battery_cc_to_ua(ddata, sample, acc, offset);
|
||||
}
|
||||
|
||||
static int cpcap_battery_get_charger_status(struct cpcap_battery_ddata *ddata,
|
||||
int *val)
|
||||
{
|
||||
union power_supply_propval prop;
|
||||
struct power_supply *charger;
|
||||
int error;
|
||||
|
||||
charger = power_supply_get_by_name("usb");
|
||||
if (!charger)
|
||||
return -ENODEV;
|
||||
|
||||
error = power_supply_get_property(charger, POWER_SUPPLY_PROP_STATUS,
|
||||
&prop);
|
||||
if (error)
|
||||
*val = POWER_SUPPLY_STATUS_UNKNOWN;
|
||||
else
|
||||
*val = prop.intval;
|
||||
|
||||
power_supply_put(charger);
|
||||
|
||||
return error;
|
||||
}
|
||||
|
||||
static bool cpcap_battery_full(struct cpcap_battery_ddata *ddata)
|
||||
{
|
||||
struct cpcap_battery_state_data *state = cpcap_battery_latest(ddata);
|
||||
unsigned int vfull;
|
||||
int error, val;
|
||||
|
||||
if (state->voltage >=
|
||||
(ddata->config.bat.constant_charge_voltage_max_uv - 18000))
|
||||
return true;
|
||||
error = cpcap_battery_get_charger_status(ddata, &val);
|
||||
if (!error) {
|
||||
switch (val) {
|
||||
case POWER_SUPPLY_STATUS_DISCHARGING:
|
||||
dev_dbg(ddata->dev, "charger disconnected\n");
|
||||
ddata->is_full = 0;
|
||||
break;
|
||||
case POWER_SUPPLY_STATUS_FULL:
|
||||
dev_dbg(ddata->dev, "charger full status\n");
|
||||
ddata->is_full = 1;
|
||||
break;
|
||||
default:
|
||||
break;
|
||||
}
|
||||
}
|
||||
|
||||
return false;
|
||||
/*
|
||||
* The full battery voltage here can be inaccurate, it's used just to
|
||||
* filter out any trickle charging events. We clear the is_full status
|
||||
* on charger disconnect above anyways.
|
||||
*/
|
||||
vfull = ddata->config.bat.constant_charge_voltage_max_uv - 120000;
|
||||
|
||||
if (ddata->is_full && state->voltage < vfull)
|
||||
ddata->is_full = 0;
|
||||
|
||||
return ddata->is_full;
|
||||
}
|
||||
|
||||
static int cpcap_battery_update_status(struct cpcap_battery_ddata *ddata)
|
||||
|
|
Loading…