[TG3]: Prescaler fix
Internal hardware timers become inaccurate after link events. Clock frequency switches performed by the CPMU fail to adjust timer prescalers. The fix is to detect core clock frequency changes during link events and adjust the timer prescalers accordingly. Signed-off-by: Matt Carlson <mcarlson@broadcom.com> Signed-off-by: Michael Chan <mchan@broadcom.com> Signed-off-by: David S. Miller <davem@davemloft.net>
This commit is contained in:
parent
5f60891b80
commit
aa6c91fe59
|
@ -3154,6 +3154,22 @@ static int tg3_setup_phy(struct tg3 *tp, int force_reset)
|
|||
err = tg3_setup_copper_phy(tp, force_reset);
|
||||
}
|
||||
|
||||
if (tp->pci_chip_rev_id == CHIPREV_ID_5784_A0) {
|
||||
u32 val, scale;
|
||||
|
||||
val = tr32(TG3_CPMU_CLCK_STAT) & CPMU_CLCK_STAT_MAC_CLCK_MASK;
|
||||
if (val == CPMU_CLCK_STAT_MAC_CLCK_62_5)
|
||||
scale = 65;
|
||||
else if (val == CPMU_CLCK_STAT_MAC_CLCK_6_25)
|
||||
scale = 6;
|
||||
else
|
||||
scale = 12;
|
||||
|
||||
val = tr32(GRC_MISC_CFG) & ~GRC_MISC_CFG_PRESCALAR_MASK;
|
||||
val |= (scale << GRC_MISC_CFG_PRESCALAR_SHIFT);
|
||||
tw32(GRC_MISC_CFG, val);
|
||||
}
|
||||
|
||||
if (tp->link_config.active_speed == SPEED_1000 &&
|
||||
tp->link_config.active_duplex == DUPLEX_HALF)
|
||||
tw32(MAC_TX_LENGTHS,
|
||||
|
|
|
@ -874,7 +874,14 @@
|
|||
#define TG3_CPMU_HST_ACC 0x0000361c
|
||||
#define CPMU_HST_ACC_MACCLK_MASK 0x001f0000
|
||||
#define CPMU_HST_ACC_MACCLK_6_25 0x00130000
|
||||
/* 0x3620 --> 0x365c unused */
|
||||
/* 0x3620 --> 0x3630 unused */
|
||||
|
||||
#define TG3_CPMU_CLCK_STAT 0x00003630
|
||||
#define CPMU_CLCK_STAT_MAC_CLCK_MASK 0x001f0000
|
||||
#define CPMU_CLCK_STAT_MAC_CLCK_62_5 0x00000000
|
||||
#define CPMU_CLCK_STAT_MAC_CLCK_12_5 0x00110000
|
||||
#define CPMU_CLCK_STAT_MAC_CLCK_6_25 0x00130000
|
||||
/* 0x3634 --> 0x365c unused */
|
||||
|
||||
#define TG3_CPMU_MUTEX_REQ 0x0000365c
|
||||
#define CPMU_MUTEX_REQ_DRIVER 0x00001000
|
||||
|
|
Loading…