ARM: mvebu: fix compatible strings of MBus on Armada 375 and Armada 38x
Due to the special handling of window 13 on Armada 375 and Armada 38x (similar to Armada XP), the MBus hardware block is *not* compatible with the one used on Armada 370. Using the Armada 370 compatible string on Armada 375 and 38x will lead to a non-working device if window 13 ends up being used. Signed-off-by: Thomas Petazzoni <thomas.petazzoni@free-electrons.com> Signed-off-by: Andrew Lunn <andrew@lunn.ch>
This commit is contained in:
parent
ddefbdb4c0
commit
a9e274c42d
|
@ -63,7 +63,7 @@
|
|||
};
|
||||
|
||||
soc {
|
||||
compatible = "marvell,armada375-mbus", "marvell,armada370-mbus", "simple-bus";
|
||||
compatible = "marvell,armada375-mbus", "simple-bus";
|
||||
#address-cells = <2>;
|
||||
#size-cells = <1>;
|
||||
controller = <&mbusc>;
|
||||
|
|
|
@ -31,8 +31,7 @@
|
|||
};
|
||||
|
||||
soc {
|
||||
compatible = "marvell,armada380-mbus", "marvell,armada370-mbus",
|
||||
"simple-bus";
|
||||
compatible = "marvell,armada380-mbus", "simple-bus";
|
||||
#address-cells = <2>;
|
||||
#size-cells = <1>;
|
||||
controller = <&mbusc>;
|
||||
|
|
Loading…
Reference in New Issue