arm64: dts: ti: iot2050: Prepare for adding 2nd-generation boards
The current IOT2050 devices are Product Generation 1 (PG1), using SR1.0 AM65x silicon. Upcoming PG2 devices will use SR2.x SoCs and will therefore need separate device trees. Prepare for that by factoring out common bits that will be shared across both generations. At this chance, drop a link to the product homepage to in the top-level dts files. Also fix a typo in my email address in some headers. Signed-off-by: Jan Kiszka <jan.kiszka@siemens.com> Signed-off-by: Nishanth Menon <nm@ti.com> Link: https://lore.kernel.org/r/31fece05f9728a852c0632985c4fa537cced4ece.1632657917.git.jan.kiszka@web.de
This commit is contained in:
parent
4f535a0e38
commit
a9dbf044c6
|
@ -0,0 +1,46 @@
|
|||
// SPDX-License-Identifier: GPL-2.0
|
||||
/*
|
||||
* Copyright (c) Siemens AG, 2021
|
||||
*
|
||||
* Authors:
|
||||
* Jan Kiszka <jan.kiszka@siemens.com>
|
||||
*
|
||||
* Common bits of the IOT2050 Basic and Advanced variants, PG1
|
||||
*/
|
||||
|
||||
&dss {
|
||||
assigned-clocks = <&k3_clks 67 2>;
|
||||
assigned-clock-parents = <&k3_clks 67 5>;
|
||||
};
|
||||
|
||||
&serdes0 {
|
||||
status = "disabled";
|
||||
};
|
||||
|
||||
&sdhci1 {
|
||||
no-1-8-v;
|
||||
};
|
||||
|
||||
&tx_pru0_0 {
|
||||
status = "disabled";
|
||||
};
|
||||
|
||||
&tx_pru0_1 {
|
||||
status = "disabled";
|
||||
};
|
||||
|
||||
&tx_pru1_0 {
|
||||
status = "disabled";
|
||||
};
|
||||
|
||||
&tx_pru1_1 {
|
||||
status = "disabled";
|
||||
};
|
||||
|
||||
&tx_pru2_0 {
|
||||
status = "disabled";
|
||||
};
|
||||
|
||||
&tx_pru2_1 {
|
||||
status = "disabled";
|
||||
};
|
|
@ -4,13 +4,11 @@
|
|||
*
|
||||
* Authors:
|
||||
* Le Jin <le.jin@siemens.com>
|
||||
* Jan Kiszka <jan.kiszk@siemens.com>
|
||||
* Jan Kiszka <jan.kiszka@siemens.com>
|
||||
*
|
||||
* Common bits of the IOT2050 Basic and Advanced variants
|
||||
* Common bits of the IOT2050 Basic and Advanced variants, PG1 and PG2
|
||||
*/
|
||||
|
||||
/dts-v1/;
|
||||
|
||||
#include "k3-am654.dtsi"
|
||||
#include <dt-bindings/phy/phy.h>
|
||||
|
||||
|
@ -557,7 +555,6 @@
|
|||
pinctrl-0 = <&main_mmc1_pins_default>;
|
||||
ti,driver-strength-ohm = <50>;
|
||||
disable-wp;
|
||||
no-1-8-v;
|
||||
};
|
||||
|
||||
&usb0 {
|
||||
|
@ -631,10 +628,6 @@
|
|||
};
|
||||
};
|
||||
|
||||
&serdes0 {
|
||||
status = "disabled";
|
||||
};
|
||||
|
||||
&pcie0_rc {
|
||||
status = "disabled";
|
||||
};
|
||||
|
@ -738,27 +731,3 @@
|
|||
&icssg2_mdio {
|
||||
status = "disabled";
|
||||
};
|
||||
|
||||
&tx_pru0_0 {
|
||||
status = "disabled";
|
||||
};
|
||||
|
||||
&tx_pru0_1 {
|
||||
status = "disabled";
|
||||
};
|
||||
|
||||
&tx_pru1_0 {
|
||||
status = "disabled";
|
||||
};
|
||||
|
||||
&tx_pru1_1 {
|
||||
status = "disabled";
|
||||
};
|
||||
|
||||
&tx_pru2_0 {
|
||||
status = "disabled";
|
||||
};
|
||||
|
||||
&tx_pru2_1 {
|
||||
status = "disabled";
|
||||
};
|
||||
|
|
|
@ -0,0 +1,60 @@
|
|||
// SPDX-License-Identifier: GPL-2.0
|
||||
/*
|
||||
* Copyright (c) Siemens AG, 2018-2021
|
||||
*
|
||||
* Authors:
|
||||
* Le Jin <le.jin@siemens.com>
|
||||
* Jan Kiszka <jan.kiszka@siemens.com>
|
||||
*
|
||||
* Common bits of the IOT2050 Basic variant, PG1 and PG2
|
||||
*/
|
||||
|
||||
#include "k3-am65-iot2050-common.dtsi"
|
||||
|
||||
/ {
|
||||
memory@80000000 {
|
||||
device_type = "memory";
|
||||
/* 1G RAM */
|
||||
reg = <0x00000000 0x80000000 0x00000000 0x40000000>;
|
||||
};
|
||||
|
||||
cpus {
|
||||
cpu-map {
|
||||
/delete-node/ cluster1;
|
||||
};
|
||||
/delete-node/ cpu@100;
|
||||
/delete-node/ cpu@101;
|
||||
};
|
||||
|
||||
/delete-node/ l2-cache1;
|
||||
};
|
||||
|
||||
/* eMMC */
|
||||
&sdhci0 {
|
||||
status = "disabled";
|
||||
};
|
||||
|
||||
&main_pmx0 {
|
||||
main_uart0_pins_default: main-uart0-pins-default {
|
||||
pinctrl-single,pins = <
|
||||
AM65X_IOPAD(0x01e4, PIN_INPUT, 0) /* (AF11) UART0_RXD */
|
||||
AM65X_IOPAD(0x01e8, PIN_OUTPUT, 0) /* (AE11) UART0_TXD */
|
||||
AM65X_IOPAD(0x01ec, PIN_INPUT, 0) /* (AG11) UART0_CTSn */
|
||||
AM65X_IOPAD(0x01f0, PIN_OUTPUT, 0) /* (AD11) UART0_RTSn */
|
||||
AM65X_IOPAD(0x0188, PIN_INPUT, 1) /* (D25) UART0_DCDn */
|
||||
AM65X_IOPAD(0x018c, PIN_INPUT, 1) /* (B26) UART0_DSRn */
|
||||
AM65X_IOPAD(0x0190, PIN_OUTPUT, 1) /* (A24) UART0_DTRn */
|
||||
AM65X_IOPAD(0x0194, PIN_INPUT, 1) /* (E24) UART0_RIN */
|
||||
>;
|
||||
};
|
||||
};
|
||||
|
||||
&main_uart0 {
|
||||
pinctrl-names = "default";
|
||||
pinctrl-0 = <&main_uart0_pins_default>;
|
||||
};
|
||||
|
||||
&mcu_r5fss0 {
|
||||
/* lock-step mode not supported on Basic boards */
|
||||
ti,cluster-mode = <0>;
|
||||
};
|
|
@ -4,63 +4,21 @@
|
|||
*
|
||||
* Authors:
|
||||
* Le Jin <le.jin@siemens.com>
|
||||
* Jan Kiszka <jan.kiszk@siemens.com>
|
||||
* Jan Kiszka <jan.kiszka@siemens.com>
|
||||
*
|
||||
* AM6528-based (dual-core) IOT2050 Basic variant
|
||||
* AM6528-based (dual-core) IOT2050 Basic variant, Product Generation 1
|
||||
* 1 GB RAM, no eMMC, main_uart0 on connector X30
|
||||
*
|
||||
* Product homepage:
|
||||
* https://new.siemens.com/global/en/products/automation/pc-based/iot-gateways/simatic-iot2050.html
|
||||
*/
|
||||
|
||||
/dts-v1/;
|
||||
|
||||
#include "k3-am65-iot2050-common.dtsi"
|
||||
#include "k3-am6528-iot2050-basic-common.dtsi"
|
||||
#include "k3-am65-iot2050-common-pg1.dtsi"
|
||||
|
||||
/ {
|
||||
compatible = "siemens,iot2050-basic", "ti,am654";
|
||||
model = "SIMATIC IOT2050 Basic";
|
||||
|
||||
memory@80000000 {
|
||||
device_type = "memory";
|
||||
/* 1G RAM */
|
||||
reg = <0x00000000 0x80000000 0x00000000 0x40000000>;
|
||||
};
|
||||
|
||||
cpus {
|
||||
cpu-map {
|
||||
/delete-node/ cluster1;
|
||||
};
|
||||
/delete-node/ cpu@100;
|
||||
/delete-node/ cpu@101;
|
||||
};
|
||||
|
||||
/delete-node/ l2-cache1;
|
||||
};
|
||||
|
||||
/* eMMC */
|
||||
&sdhci0 {
|
||||
status = "disabled";
|
||||
};
|
||||
|
||||
&main_pmx0 {
|
||||
main_uart0_pins_default: main-uart0-pins-default {
|
||||
pinctrl-single,pins = <
|
||||
AM65X_IOPAD(0x01e4, PIN_INPUT, 0) /* (AF11) UART0_RXD */
|
||||
AM65X_IOPAD(0x01e8, PIN_OUTPUT, 0) /* (AE11) UART0_TXD */
|
||||
AM65X_IOPAD(0x01ec, PIN_INPUT, 0) /* (AG11) UART0_CTSn */
|
||||
AM65X_IOPAD(0x01f0, PIN_OUTPUT, 0) /* (AD11) UART0_RTSn */
|
||||
AM65X_IOPAD(0x0188, PIN_INPUT, 1) /* (D25) UART0_DCDn */
|
||||
AM65X_IOPAD(0x018c, PIN_INPUT, 1) /* (B26) UART0_DSRn */
|
||||
AM65X_IOPAD(0x0190, PIN_OUTPUT, 1) /* (A24) UART0_DTRn */
|
||||
AM65X_IOPAD(0x0194, PIN_INPUT, 1) /* (E24) UART0_RIN */
|
||||
>;
|
||||
};
|
||||
};
|
||||
|
||||
&main_uart0 {
|
||||
pinctrl-names = "default";
|
||||
pinctrl-0 = <&main_uart0_pins_default>;
|
||||
};
|
||||
|
||||
&mcu_r5fss0 {
|
||||
/* lock-step mode not supported on this board */
|
||||
ti,cluster-mode = <0>;
|
||||
};
|
||||
|
|
|
@ -0,0 +1,56 @@
|
|||
// SPDX-License-Identifier: GPL-2.0
|
||||
/*
|
||||
* Copyright (c) Siemens AG, 2018-2021
|
||||
*
|
||||
* Authors:
|
||||
* Le Jin <le.jin@siemens.com>
|
||||
* Jan Kiszka <jan.kiszka@siemens.com>
|
||||
*
|
||||
* Common bits of the IOT2050 Advanced variant, PG1 and PG2
|
||||
*/
|
||||
|
||||
/dts-v1/;
|
||||
|
||||
#include "k3-am65-iot2050-common.dtsi"
|
||||
|
||||
/ {
|
||||
memory@80000000 {
|
||||
device_type = "memory";
|
||||
/* 2G RAM */
|
||||
reg = <0x00000000 0x80000000 0x00000000 0x80000000>;
|
||||
};
|
||||
};
|
||||
|
||||
&main_pmx0 {
|
||||
main_mmc0_pins_default: main-mmc0-pins-default {
|
||||
pinctrl-single,pins = <
|
||||
AM65X_IOPAD(0x01a8, PIN_INPUT_PULLDOWN, 0) /* (B25) MMC0_CLK */
|
||||
AM65X_IOPAD(0x01ac, PIN_INPUT_PULLUP, 0) /* (B27) MMC0_CMD */
|
||||
AM65X_IOPAD(0x01a4, PIN_INPUT_PULLUP, 0) /* (A26) MMC0_DAT0 */
|
||||
AM65X_IOPAD(0x01a0, PIN_INPUT_PULLUP, 0) /* (E25) MMC0_DAT1 */
|
||||
AM65X_IOPAD(0x019c, PIN_INPUT_PULLUP, 0) /* (C26) MMC0_DAT2 */
|
||||
AM65X_IOPAD(0x0198, PIN_INPUT_PULLUP, 0) /* (A25) MMC0_DAT3 */
|
||||
AM65X_IOPAD(0x0194, PIN_INPUT_PULLUP, 0) /* (E24) MMC0_DAT4 */
|
||||
AM65X_IOPAD(0x0190, PIN_INPUT_PULLUP, 0) /* (A24) MMC0_DAT5 */
|
||||
AM65X_IOPAD(0x018c, PIN_INPUT_PULLUP, 0) /* (B26) MMC0_DAT6 */
|
||||
AM65X_IOPAD(0x0188, PIN_INPUT_PULLUP, 0) /* (D25) MMC0_DAT7 */
|
||||
AM65X_IOPAD(0x01b8, PIN_OUTPUT_PULLUP, 7) /* (B23) MMC0_SDWP */
|
||||
AM65X_IOPAD(0x01b4, PIN_INPUT_PULLUP, 0) /* (A23) MMC0_SDCD */
|
||||
AM65X_IOPAD(0x01b0, PIN_INPUT, 0) /* (C25) MMC0_DS */
|
||||
>;
|
||||
};
|
||||
};
|
||||
|
||||
/* eMMC */
|
||||
&sdhci0 {
|
||||
pinctrl-names = "default";
|
||||
pinctrl-0 = <&main_mmc0_pins_default>;
|
||||
bus-width = <8>;
|
||||
non-removable;
|
||||
ti,driver-strength-ohm = <50>;
|
||||
disable-wp;
|
||||
};
|
||||
|
||||
&main_uart0 {
|
||||
status = "disabled";
|
||||
};
|
|
@ -4,57 +4,21 @@
|
|||
*
|
||||
* Authors:
|
||||
* Le Jin <le.jin@siemens.com>
|
||||
* Jan Kiszka <jan.kiszk@siemens.com>
|
||||
* Jan Kiszka <jan.kiszka@siemens.com>
|
||||
*
|
||||
* AM6548-based (quad-core) IOT2050 Advanced variant
|
||||
* AM6548-based (quad-core) IOT2050 Advanced variant, Product Generation 1
|
||||
* 2 GB RAM, 16 GB eMMC, USB-serial converter on connector X30
|
||||
*
|
||||
* Product homepage:
|
||||
* https://new.siemens.com/global/en/products/automation/pc-based/iot-gateways/simatic-iot2050.html
|
||||
*/
|
||||
|
||||
/dts-v1/;
|
||||
|
||||
#include "k3-am65-iot2050-common.dtsi"
|
||||
#include "k3-am6548-iot2050-advanced-common.dtsi"
|
||||
#include "k3-am65-iot2050-common-pg1.dtsi"
|
||||
|
||||
/ {
|
||||
compatible = "siemens,iot2050-advanced", "ti,am654";
|
||||
model = "SIMATIC IOT2050 Advanced";
|
||||
|
||||
memory@80000000 {
|
||||
device_type = "memory";
|
||||
/* 2G RAM */
|
||||
reg = <0x00000000 0x80000000 0x00000000 0x80000000>;
|
||||
};
|
||||
};
|
||||
|
||||
&main_pmx0 {
|
||||
main_mmc0_pins_default: main-mmc0-pins-default {
|
||||
pinctrl-single,pins = <
|
||||
AM65X_IOPAD(0x01a8, PIN_INPUT_PULLDOWN, 0) /* (B25) MMC0_CLK */
|
||||
AM65X_IOPAD(0x01ac, PIN_INPUT_PULLUP, 0) /* (B27) MMC0_CMD */
|
||||
AM65X_IOPAD(0x01a4, PIN_INPUT_PULLUP, 0) /* (A26) MMC0_DAT0 */
|
||||
AM65X_IOPAD(0x01a0, PIN_INPUT_PULLUP, 0) /* (E25) MMC0_DAT1 */
|
||||
AM65X_IOPAD(0x019c, PIN_INPUT_PULLUP, 0) /* (C26) MMC0_DAT2 */
|
||||
AM65X_IOPAD(0x0198, PIN_INPUT_PULLUP, 0) /* (A25) MMC0_DAT3 */
|
||||
AM65X_IOPAD(0x0194, PIN_INPUT_PULLUP, 0) /* (E24) MMC0_DAT4 */
|
||||
AM65X_IOPAD(0x0190, PIN_INPUT_PULLUP, 0) /* (A24) MMC0_DAT5 */
|
||||
AM65X_IOPAD(0x018c, PIN_INPUT_PULLUP, 0) /* (B26) MMC0_DAT6 */
|
||||
AM65X_IOPAD(0x0188, PIN_INPUT_PULLUP, 0) /* (D25) MMC0_DAT7 */
|
||||
AM65X_IOPAD(0x01b8, PIN_OUTPUT_PULLUP, 7) /* (B23) MMC0_SDWP */
|
||||
AM65X_IOPAD(0x01b4, PIN_INPUT_PULLUP, 0) /* (A23) MMC0_SDCD */
|
||||
AM65X_IOPAD(0x01b0, PIN_INPUT, 0) /* (C25) MMC0_DS */
|
||||
>;
|
||||
};
|
||||
};
|
||||
|
||||
/* eMMC */
|
||||
&sdhci0 {
|
||||
pinctrl-names = "default";
|
||||
pinctrl-0 = <&main_mmc0_pins_default>;
|
||||
bus-width = <8>;
|
||||
non-removable;
|
||||
ti,driver-strength-ohm = <50>;
|
||||
disable-wp;
|
||||
};
|
||||
|
||||
&main_uart0 {
|
||||
status = "disabled";
|
||||
};
|
||||
|
|
Loading…
Reference in New Issue