HID: amd_sfh: Increase sensor command timeout
HPD sensors take more time to initialize. Hence increasing sensor
command timeout to get response with status within a max timeout.
Fixes: 173709f50e
("HID: amd_sfh: Add command response to check command status")
Signed-off-by: Basavaraj Natikar <Basavaraj.Natikar@amd.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
This commit is contained in:
parent
2787710f73
commit
a7072c01c3
|
@ -37,11 +37,11 @@ static int amd_sfh_wait_response_v2(struct amd_mp2_dev *mp2, u8 sid, u32 sensor_
|
|||
{
|
||||
union cmd_response cmd_resp;
|
||||
|
||||
/* Get response with status within a max of 800 ms timeout */
|
||||
/* Get response with status within a max of 1600 ms timeout */
|
||||
if (!readl_poll_timeout(mp2->mmio + AMD_P2C_MSG(0), cmd_resp.resp,
|
||||
(cmd_resp.response_v2.response == sensor_sts &&
|
||||
cmd_resp.response_v2.status == 0 && (sid == 0xff ||
|
||||
cmd_resp.response_v2.sensor_id == sid)), 500, 800000))
|
||||
cmd_resp.response_v2.sensor_id == sid)), 500, 1600000))
|
||||
return cmd_resp.response_v2.response;
|
||||
|
||||
return SENSOR_DISABLED;
|
||||
|
|