drivers: sh: Disable PM runtime for multi-platform r8a7740 with genpd

If the default PM domain using PM_CLK is used for PM runtime, the real PM
domain(s) cannot be registered from DT later.

Hence do not enable it when running a multi-platform kernel with genpd
support on an r8a7740. The R-Mobile PM domain driver will take care of
PM runtime management of the module clocks.

The default PM domain is still needed for:
  - platforms without genpd support,
  - the legacy (non-DT) case, where genpd may take over later, except
    for the C5 "always on" PM domain.

Signed-off-by: Geert Uytterhoeven <geert+renesas@glider.be>
Signed-off-by: Simon Horman <horms+renesas@verge.net.au>
This commit is contained in:
Geert Uytterhoeven 2014-12-03 14:41:47 +01:00 committed by Simon Horman
parent c517d838eb
commit a5cb514f1f
1 changed files with 2 additions and 0 deletions

View File

@ -81,7 +81,9 @@ static int __init sh_pm_runtime_init(void)
if (!of_machine_is_compatible("renesas,emev2") && if (!of_machine_is_compatible("renesas,emev2") &&
!of_machine_is_compatible("renesas,r7s72100") && !of_machine_is_compatible("renesas,r7s72100") &&
!of_machine_is_compatible("renesas,r8a73a4") && !of_machine_is_compatible("renesas,r8a73a4") &&
#ifndef CONFIG_PM_GENERIC_DOMAINS_OF
!of_machine_is_compatible("renesas,r8a7740") && !of_machine_is_compatible("renesas,r8a7740") &&
#endif
!of_machine_is_compatible("renesas,r8a7778") && !of_machine_is_compatible("renesas,r8a7778") &&
!of_machine_is_compatible("renesas,r8a7779") && !of_machine_is_compatible("renesas,r8a7779") &&
!of_machine_is_compatible("renesas,r8a7790") && !of_machine_is_compatible("renesas,r8a7790") &&