wl12xx: Power off after flushing work

When stopping plt, the chip is powered off before all current work items
are flushed and interrupts are disabled. This might introduce a race in
which the driver tries to communicate with a powered off chip.

Fix this by powering off the device only after interrupts are disabled
and all work items are flushed.

Signed-off-by: Ido Yariv <ido@wizery.com>
Signed-off-by: Luciano Coelho <coelho@ti.com>
This commit is contained in:
Ido Yariv 2012-01-11 09:42:40 +02:00 committed by Luciano Coelho
parent f3df1331f2
commit a454969ede
1 changed files with 5 additions and 2 deletions

View File

@ -1406,8 +1406,6 @@ int wl1271_plt_stop(struct wl1271 *wl)
goto out;
}
wl1271_power_off(wl);
wl->state = WL1271_STATE_OFF;
wl->rx_counter = 0;
@ -1417,6 +1415,11 @@ int wl1271_plt_stop(struct wl1271 *wl)
wl1271_flush_deferred_work(wl);
cancel_work_sync(&wl->netstack_work);
cancel_work_sync(&wl->recovery_work);
mutex_lock(&wl->mutex);
wl1271_power_off(wl);
mutex_unlock(&wl->mutex);
out:
return ret;
}