wl12xx: Power off after flushing work
When stopping plt, the chip is powered off before all current work items are flushed and interrupts are disabled. This might introduce a race in which the driver tries to communicate with a powered off chip. Fix this by powering off the device only after interrupts are disabled and all work items are flushed. Signed-off-by: Ido Yariv <ido@wizery.com> Signed-off-by: Luciano Coelho <coelho@ti.com>
This commit is contained in:
parent
f3df1331f2
commit
a454969ede
|
@ -1406,8 +1406,6 @@ int wl1271_plt_stop(struct wl1271 *wl)
|
|||
goto out;
|
||||
}
|
||||
|
||||
wl1271_power_off(wl);
|
||||
|
||||
wl->state = WL1271_STATE_OFF;
|
||||
wl->rx_counter = 0;
|
||||
|
||||
|
@ -1417,6 +1415,11 @@ int wl1271_plt_stop(struct wl1271 *wl)
|
|||
wl1271_flush_deferred_work(wl);
|
||||
cancel_work_sync(&wl->netstack_work);
|
||||
cancel_work_sync(&wl->recovery_work);
|
||||
|
||||
mutex_lock(&wl->mutex);
|
||||
wl1271_power_off(wl);
|
||||
mutex_unlock(&wl->mutex);
|
||||
|
||||
out:
|
||||
return ret;
|
||||
}
|
||||
|
|