ARM: dts: r8a7779: Use SYSC "always-on" PM Domain for HSCIF

Hook up HSCIF serial devices that are part of the CPG/MSTP Clock Domain
to the SYSC "always-on" PM Domain, for a more consistent
device-power-area description in DT.

Cfr. commit 751e29bbb6 ("ARM: dts: r8a7779: Use SYSC "always-on"
PM Domain").

Fixes: 055d15a88f ("ARM: dts: r8a7779: Add HSCIF0/1 device nodes")
Signed-off-by: Geert Uytterhoeven <geert+renesas@glider.be>
Reviewed-by: Simon Horman <horms+renesas@verge.net.au>
Reviewed-by: Ulrich Hecht <uli+renesas@fpond.eu>
This commit is contained in:
Geert Uytterhoeven 2019-08-16 10:22:29 +02:00
parent 5f9e832c13
commit a03fa77d85
1 changed files with 2 additions and 2 deletions

View File

@ -296,7 +296,7 @@
<&cpg_clocks R8A7779_CLK_S>,
<&scif_clk>;
clock-names = "fck", "brg_int", "scif_clk";
power-domains = <&cpg_clocks>;
power-domains = <&sysc R8A7779_PD_ALWAYS_ON>;
status = "disabled";
};
@ -309,7 +309,7 @@
<&cpg_clocks R8A7779_CLK_S>,
<&scif_clk>;
clock-names = "fck", "brg_int", "scif_clk";
power-domains = <&cpg_clocks>;
power-domains = <&sysc R8A7779_PD_ALWAYS_ON>;
status = "disabled";
};