[ARM] 4052/1: S3C24XX: Fix PM in arch/arm/mach-s3c2410/Kconfig

Fix up the CONFIG_PM mixups in arch/arm/mach-s3c2410/Kconfig
causing CONFIG_S3C2410_PM and CONFIG_PM_H1940 to get enabled
permanently.

Signed-off-by: Ben Dooks <ben-linux@fluff.org>
Signed-off-by: Russell King <rmk+kernel@arm.linux.org.uk>
This commit is contained in:
Ben Dooks 2006-12-18 00:39:47 +01:00 committed by Russell King
parent 255d1f8639
commit 9bcb533c13
1 changed files with 6 additions and 9 deletions

View File

@ -43,14 +43,13 @@ config BAST_PC104_IRQ
config PM_H1940
bool
depends on PM
help
Internal node for H1940 and related PM
config ARCH_H1940
bool "IPAQ H1940"
select CPU_S3C2410
select PM_H1940
select PM_H1940 if PM
help
Say Y here if you are using the HP IPAQ H1940
@ -122,7 +121,7 @@ config MACH_VR1000
config MACH_RX3715
bool "HP iPAQ rx3715"
select CPU_S3C2440
select PM_H1940
select PM_H1940 if PM
help
Say Y here if you are using the HP iPAQ rx3715.
@ -156,7 +155,6 @@ config S3C2410_CLOCK
config S3C2410_PM
bool
depends on CONFIG_PM
help
Power Management code common to S3C2410 and better
@ -171,7 +169,7 @@ config CPU_S3C2410
bool
depends on ARCH_S3C2410
select S3C2410_CLOCK
select S3C2410_PM
select S3C2410_PM if PM
help
Support for S3C2410 and S3C2410A family from the S3C24XX line
of Samsung Mobile CPUs.
@ -186,14 +184,13 @@ config CPU_S3C2412_ONLY
config S3C2412_PM
bool
default y if PM
depends on CPU_S3C2412
help
Internal config node to apply S3C2412 power management
config CPU_S3C2412
bool
depends on ARCH_S3C2410
select S3C2412_PM if PM
help
Support for the S3C2412 and S3C2413 SoCs from the S3C24XX line
@ -207,7 +204,7 @@ config CPU_S3C2440
bool
depends on ARCH_S3C2410
select S3C2410_CLOCK
select S3C2410_PM
select S3C2410_PM if PM
select CPU_S3C244X
help
Support for S3C2440 Samsung Mobile CPU based systems.
@ -216,7 +213,7 @@ config CPU_S3C2442
bool
depends on ARCH_S3C2420
select S3C2410_CLOCK
select S3C2410_PM
select S3C2410_PM if PM
select CPU_S3C244X
help
Support for S3C2442 Samsung Mobile CPU based systems.