dt-bindings: power: Introduce one property to describe the battery resistance with temperature changes
Since the battery internal resistance can be changed as the temperature changes, thus add one table to describe the battery resistance percent in different temperatures to get a accurate battery internal resistance. Reviewed-by: Rob Herring <robh@kernel.org> Signed-off-by: Baolin Wang <baolin.wang@linaro.org> Signed-off-by: Baolin Wang <baolin.wang7@gmail.com> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
This commit is contained in:
parent
5de1780181
commit
9a056a8791
|
@ -35,6 +35,10 @@ Optional Properties:
|
|||
for each of the battery capacity lookup table. The first temperature value
|
||||
specifies the OCV table 0, and the second temperature value specifies the
|
||||
OCV table 1, and so on.
|
||||
- resistance-temp-table: An array providing the temperature in degree Celsius
|
||||
and corresponding battery internal resistance percent, which is used to look
|
||||
up the resistance percent according to current temperature to get a accurate
|
||||
batterty internal resistance in different temperatures.
|
||||
|
||||
Battery properties are named, where possible, for the corresponding
|
||||
elements in enum power_supply_property, defined in
|
||||
|
@ -61,6 +65,7 @@ Example:
|
|||
ocv-capacity-table-0 = <4185000 100>, <4113000 95>, <4066000 90>, ...;
|
||||
ocv-capacity-table-1 = <4200000 100>, <4185000 95>, <4113000 90>, ...;
|
||||
ocv-capacity-table-2 = <4250000 100>, <4200000 95>, <4185000 90>, ...;
|
||||
resistance-temp-table = <20 100>, <10 90>, <0 80>, <(-10) 60>;
|
||||
};
|
||||
|
||||
charger: charger@11 {
|
||||
|
|
Loading…