ARM: 6530/1: mmci: partially revert clock divisor code
I misread the datasheet as if bypass mode was not available at all on the ux500's, I was wrong. It is there, the datasheet just states that you should not have to use it. Signed-off-by: Linus Walleij <linus.walleij@stericsson.com> Signed-off-by: Russell King <rmk+kernel@arm.linux.org.uk>
This commit is contained in:
parent
b70a67f938
commit
991a86e182
|
@ -101,13 +101,7 @@ static void mmci_set_clkreg(struct mmci_host *host, unsigned int desired)
|
|||
|
||||
if (desired) {
|
||||
if (desired >= host->mclk) {
|
||||
/*
|
||||
* The ST clock divider does not like the bypass bit,
|
||||
* even though it's available. Instead the datasheet
|
||||
* recommends setting the divider to zero.
|
||||
*/
|
||||
if (!variant->st_clkdiv)
|
||||
clk = MCI_CLK_BYPASS;
|
||||
clk = MCI_CLK_BYPASS;
|
||||
host->cclk = host->mclk;
|
||||
} else if (variant->st_clkdiv) {
|
||||
/*
|
||||
|
|
Loading…