net/mlx5e: Use correct enum to determine uplink port
For vlan push action, if eswitch flow source capability is enabled, flow source value compared with MLX5_VPORT_UPLINK enum, to determine uplink port. This lead to syndrome in dmesg if try to add vlan push action. For example: $ tc filter add dev vxlan0 ingress protocol ip prio 1 flower \ enc_dst_port 4789 \ action tunnel_key unset pipe \ action vlan push id 20 pipe \ action mirred egress redirect dev ens1f0_0 $ dmesg ... [ 2456.883693] mlx5_core 0000:82:00.0: mlx5_cmd_check:756:(pid 5273): SET_FLOW_TABLE_ENTRY(0x936) op_mod(0x0) failed, status bad parameter(0x3), syndrome (0xa9c090) Use the correct enum value MLX5_FLOW_CONTEXT_FLOW_SOURCE_UPLINK. Fixes: bb204dcf39fe ("net/mlx5e: Determine source port properly for vlan push action") Signed-off-by: Dmytro Linkin <dmitrolin@mellanox.com> Reviewed-by: Vlad Buslov <vladbu@mellanox.com> Reviewed-by: Roi Dayan <roid@mellanox.com> Signed-off-by: Saeed Mahameed <saeedm@mellanox.com>
This commit is contained in:
parent
260986fcff
commit
950d3af70e
|
@ -183,7 +183,8 @@ static bool mlx5_eswitch_offload_is_uplink_port(const struct mlx5_eswitch *esw,
|
|||
u32 port_mask, port_value;
|
||||
|
||||
if (MLX5_CAP_ESW_FLOWTABLE(esw->dev, flow_source))
|
||||
return spec->flow_context.flow_source == MLX5_VPORT_UPLINK;
|
||||
return spec->flow_context.flow_source ==
|
||||
MLX5_FLOW_CONTEXT_FLOW_SOURCE_UPLINK;
|
||||
|
||||
port_mask = MLX5_GET(fte_match_param, spec->match_criteria,
|
||||
misc_parameters.source_port);
|
||||
|
|
Loading…
Reference in New Issue