dt-bindings: mailbox : arm,mhu: Convert to Json-schema
Convert the DT binding over to Json-schema. Reviewed-by: Rob Herring <robh@kernel.org> Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org> Signed-off-by: Sudeep Holla <sudeep.holla@arm.com> Signed-off-by: Jassi Brar <jaswinder.singh@linaro.org>
This commit is contained in:
parent
5b92d8e9e5
commit
9070f35d25
|
@ -0,0 +1,87 @@
|
|||
# SPDX-License-Identifier: (GPL-2.0-only OR BSD-2-Clause)
|
||||
%YAML 1.2
|
||||
---
|
||||
$id: http://devicetree.org/schemas/mailbox/arm,mhu.yaml#
|
||||
$schema: http://devicetree.org/meta-schemas/core.yaml#
|
||||
|
||||
title: ARM MHU Mailbox Controller
|
||||
|
||||
maintainers:
|
||||
- Jassi Brar <jaswinder.singh@linaro.org>
|
||||
|
||||
description: |
|
||||
The ARM's Message-Handling-Unit (MHU) is a mailbox controller that has 3
|
||||
independent channels/links to communicate with remote processor(s). MHU links
|
||||
are hardwired on a platform. A link raises interrupt for any received data.
|
||||
However, there is no specified way of knowing if the sent data has been read
|
||||
by the remote. This driver assumes the sender polls STAT register and the
|
||||
remote clears it after having read the data. The last channel is specified to
|
||||
be a 'Secure' resource, hence can't be used by Linux running NS.
|
||||
|
||||
# We need a select here so we don't match all nodes with 'arm,primecell'
|
||||
select:
|
||||
properties:
|
||||
compatible:
|
||||
contains:
|
||||
const: arm,mhu
|
||||
required:
|
||||
- compatible
|
||||
|
||||
properties:
|
||||
compatible:
|
||||
items:
|
||||
- const: arm,mhu
|
||||
- const: arm,primecell
|
||||
|
||||
reg:
|
||||
maxItems: 1
|
||||
|
||||
interrupts:
|
||||
items:
|
||||
- description: low-priority non-secure
|
||||
- description: high-priority non-secure
|
||||
- description: Secure
|
||||
maxItems: 3
|
||||
|
||||
clocks:
|
||||
maxItems: 1
|
||||
|
||||
clock-names:
|
||||
items:
|
||||
- const: apb_pclk
|
||||
|
||||
'#mbox-cells':
|
||||
description: Index of the channel.
|
||||
const: 1
|
||||
|
||||
required:
|
||||
- compatible
|
||||
- reg
|
||||
- interrupts
|
||||
- '#mbox-cells'
|
||||
|
||||
additionalProperties: false
|
||||
|
||||
examples:
|
||||
- |
|
||||
soc {
|
||||
#address-cells = <2>;
|
||||
#size-cells = <2>;
|
||||
|
||||
mhuA: mailbox@2b1f0000 {
|
||||
#mbox-cells = <1>;
|
||||
compatible = "arm,mhu", "arm,primecell";
|
||||
reg = <0 0x2b1f0000 0 0x1000>;
|
||||
interrupts = <0 36 4>, /* LP-NonSecure */
|
||||
<0 35 4>, /* HP-NonSecure */
|
||||
<0 37 4>; /* Secure */
|
||||
clocks = <&clock 0 2 1>;
|
||||
clock-names = "apb_pclk";
|
||||
};
|
||||
|
||||
mhu_client_scb: scb@2e000000 {
|
||||
compatible = "fujitsu,mb86s70-scb-1.0";
|
||||
reg = <0 0x2e000000 0 0x4000>;
|
||||
mboxes = <&mhuA 1>; /* HP-NonSecure */
|
||||
};
|
||||
};
|
|
@ -1,43 +0,0 @@
|
|||
ARM MHU Mailbox Driver
|
||||
======================
|
||||
|
||||
The ARM's Message-Handling-Unit (MHU) is a mailbox controller that has
|
||||
3 independent channels/links to communicate with remote processor(s).
|
||||
MHU links are hardwired on a platform. A link raises interrupt for any
|
||||
received data. However, there is no specified way of knowing if the sent
|
||||
data has been read by the remote. This driver assumes the sender polls
|
||||
STAT register and the remote clears it after having read the data.
|
||||
The last channel is specified to be a 'Secure' resource, hence can't be
|
||||
used by Linux running NS.
|
||||
|
||||
Mailbox Device Node:
|
||||
====================
|
||||
|
||||
Required properties:
|
||||
--------------------
|
||||
- compatible: Shall be "arm,mhu" & "arm,primecell"
|
||||
- reg: Contains the mailbox register address range (base
|
||||
address and length)
|
||||
- #mbox-cells Shall be 1 - the index of the channel needed.
|
||||
- interrupts: Contains the interrupt information corresponding to
|
||||
each of the 3 links of MHU.
|
||||
|
||||
Example:
|
||||
--------
|
||||
|
||||
mhu: mailbox@2b1f0000 {
|
||||
#mbox-cells = <1>;
|
||||
compatible = "arm,mhu", "arm,primecell";
|
||||
reg = <0 0x2b1f0000 0x1000>;
|
||||
interrupts = <0 36 4>, /* LP-NonSecure */
|
||||
<0 35 4>, /* HP-NonSecure */
|
||||
<0 37 4>; /* Secure */
|
||||
clocks = <&clock 0 2 1>;
|
||||
clock-names = "apb_pclk";
|
||||
};
|
||||
|
||||
mhu_client: scb@2e000000 {
|
||||
compatible = "fujitsu,mb86s70-scb-1.0";
|
||||
reg = <0 0x2e000000 0x4000>;
|
||||
mboxes = <&mhu 1>; /* HP-NonSecure */
|
||||
};
|
Loading…