ath10k: fix duration calculation for quiet param
The duty cycle (% of quiet duration) is used to put the device in quiet mode for the given period. Currently the quiet duration is wrongly calculated which results in not enabling quiet mode. Fix the calculation as below duration = (period * duty cycle) / 100 Signed-off-by: Rajkumar Manoharan <rmanohar@qti.qualcomm.com> Signed-off-by: Kalle Valo <kvalo@qca.qualcomm.com>
This commit is contained in:
parent
fbb8f1b729
commit
8bdadac13f
|
@ -98,7 +98,7 @@ static int ath10k_thermal_set_cur_dutycycle(struct thermal_cooling_device *cdev,
|
|||
}
|
||||
period = max(ATH10K_QUIET_PERIOD_MIN,
|
||||
(ATH10K_QUIET_PERIOD_DEFAULT / num_bss));
|
||||
duration = period * (duty_cycle / 100);
|
||||
duration = (period * duty_cycle) / 100;
|
||||
enabled = duration ? 1 : 0;
|
||||
|
||||
ret = ath10k_wmi_pdev_set_quiet_mode(ar, period, duration,
|
||||
|
|