wil6210: fix timeout for start_pcp

It may take up to 3500ms for the FW to start AP/PCP. Increase accordingly,
adding some safety margin.

Signed-off-by: Vladimir Kondratiev <qca_vkondrat@qca.qualcomm.com>
Signed-off-by: John W. Linville <linville@tuxdriver.com>
This commit is contained in:
Vladimir Kondratiev 2013-06-09 09:12:50 +03:00 committed by John W. Linville
parent 59505c02e1
commit 8b5c7f6c2b
1 changed files with 5 additions and 1 deletions

View File

@ -739,8 +739,12 @@ int wmi_pcp_start(struct wil6210_priv *wil, int bi, u8 wmi_nettype, u8 chan)
if (!wil->secure_pcp)
cmd.disable_sec = 1;
/*
* Processing time may be huge, in case of secure AP it takes about
* 3500ms for FW to start AP
*/
rc = wmi_call(wil, WMI_PCP_START_CMDID, &cmd, sizeof(cmd),
WMI_PCP_STARTED_EVENTID, &reply, sizeof(reply), 100);
WMI_PCP_STARTED_EVENTID, &reply, sizeof(reply), 5000);
if (rc)
return rc;