HID: rmi: fix masks for x and w_x data
The F11 data in the HID report contains four bits of data for w_x and the least significant bits of x. Currently only the first three bits are being used which is resulting in small jumps in the position data on the x axis and in the w_x data. Signed-off-by: Andrew Duggan <aduggan@synaptics.com> Reviewed-by: Benjamin Tissoires <benjamin.tissoires@redhat.com> Signed-off-by: Jiri Kosina <jkosina@suse.cz>
This commit is contained in:
parent
b668fdce41
commit
876e7a8a11
|
@ -277,9 +277,9 @@ static void rmi_f11_process_touch(struct rmi_data *hdata, int slot,
|
|||
input_mt_report_slot_state(hdata->input, MT_TOOL_FINGER,
|
||||
finger_state == 0x01);
|
||||
if (finger_state == 0x01) {
|
||||
x = (touch_data[0] << 4) | (touch_data[2] & 0x07);
|
||||
x = (touch_data[0] << 4) | (touch_data[2] & 0x0F);
|
||||
y = (touch_data[1] << 4) | (touch_data[2] >> 4);
|
||||
wx = touch_data[3] & 0x07;
|
||||
wx = touch_data[3] & 0x0F;
|
||||
wy = touch_data[3] >> 4;
|
||||
wide = (wx > wy);
|
||||
major = max(wx, wy);
|
||||
|
|
Loading…