Merge branch 'fixes' of git://git.kernel.org/pub/scm/linux/kernel/git/evalenti/linux-soc-thermal
Pull thermal fixes from Eduardo Valentin: "A couple of fixes for the thermal subsystem" * 'fixes' of git://git.kernel.org/pub/scm/linux/kernel/git/evalenti/linux-soc-thermal: dt-bindings: thermal: Remove "cooling-{min|max}-level" properties dt-bindings: thermal: remove no longer needed samsung thermal properties
This commit is contained in:
commit
83beed7b2b
|
@ -49,19 +49,6 @@ on the SoC (only first trip points defined in DT will be configured):
|
|||
- samsung,exynos5433-tmu: 8
|
||||
- samsung,exynos7-tmu: 8
|
||||
|
||||
Following properties are mandatory (depending on SoC):
|
||||
- samsung,tmu_gain: Gain value for internal TMU operation.
|
||||
- samsung,tmu_reference_voltage: Value of TMU IP block's reference voltage
|
||||
- samsung,tmu_noise_cancel_mode: Mode for noise cancellation
|
||||
- samsung,tmu_efuse_value: Default level of temperature - it is needed when
|
||||
in factory fusing produced wrong value
|
||||
- samsung,tmu_min_efuse_value: Minimum temperature fused value
|
||||
- samsung,tmu_max_efuse_value: Maximum temperature fused value
|
||||
- samsung,tmu_first_point_trim: First point trimming value
|
||||
- samsung,tmu_second_point_trim: Second point trimming value
|
||||
- samsung,tmu_default_temp_offset: Default temperature offset
|
||||
- samsung,tmu_cal_type: Callibration type
|
||||
|
||||
** Optional properties:
|
||||
|
||||
- vtmu-supply: This entry is optional and provides the regulator node supplying
|
||||
|
@ -78,7 +65,7 @@ Example 1):
|
|||
clocks = <&clock 383>;
|
||||
clock-names = "tmu_apbif";
|
||||
vtmu-supply = <&tmu_regulator_node>;
|
||||
#include "exynos4412-tmu-sensor-conf.dtsi"
|
||||
#thermal-sensor-cells = <0>;
|
||||
};
|
||||
|
||||
Example 2):
|
||||
|
@ -89,7 +76,7 @@ Example 2):
|
|||
interrupts = <0 58 0>;
|
||||
clocks = <&clock 21>;
|
||||
clock-names = "tmu_apbif";
|
||||
#include "exynos5440-tmu-sensor-conf.dtsi"
|
||||
#thermal-sensor-cells = <0>;
|
||||
};
|
||||
|
||||
Example 3): (In case of Exynos5420 "with misplaced TRIMINFO register")
|
||||
|
@ -99,7 +86,7 @@ Example 3): (In case of Exynos5420 "with misplaced TRIMINFO register")
|
|||
interrupts = <0 184 0>;
|
||||
clocks = <&clock 318>, <&clock 318>;
|
||||
clock-names = "tmu_apbif", "tmu_triminfo_apbif";
|
||||
#include "exynos4412-tmu-sensor-conf.dtsi"
|
||||
#thermal-sensor-cells = <0>;
|
||||
};
|
||||
|
||||
tmu_cpu3: tmu@1006c000 {
|
||||
|
@ -108,7 +95,7 @@ Example 3): (In case of Exynos5420 "with misplaced TRIMINFO register")
|
|||
interrupts = <0 185 0>;
|
||||
clocks = <&clock 318>, <&clock 319>;
|
||||
clock-names = "tmu_apbif", "tmu_triminfo_apbif";
|
||||
#include "exynos4412-tmu-sensor-conf.dtsi"
|
||||
#thermal-sensor-cells = <0>;
|
||||
};
|
||||
|
||||
tmu_gpu: tmu@100a0000 {
|
||||
|
@ -117,7 +104,7 @@ Example 3): (In case of Exynos5420 "with misplaced TRIMINFO register")
|
|||
interrupts = <0 215 0>;
|
||||
clocks = <&clock 319>, <&clock 318>;
|
||||
clock-names = "tmu_apbif", "tmu_triminfo_apbif";
|
||||
#include "exynos4412-tmu-sensor-conf.dtsi"
|
||||
#thermal-sensor-cells = <0>;
|
||||
};
|
||||
|
||||
Note: For multi-instance tmu each instance should have an alias correctly
|
||||
|
|
|
@ -55,8 +55,7 @@ of heat dissipation). For example a fan's cooling states correspond to
|
|||
the different fan speeds possible. Cooling states are referred to by
|
||||
single unsigned integers, where larger numbers mean greater heat
|
||||
dissipation. The precise set of cooling states associated with a device
|
||||
(as referred to by the cooling-min-level and cooling-max-level
|
||||
properties) should be defined in a particular device's binding.
|
||||
should be defined in a particular device's binding.
|
||||
For more examples of cooling devices, refer to the example sections below.
|
||||
|
||||
Required properties:
|
||||
|
@ -69,15 +68,6 @@ Required properties:
|
|||
See Cooling device maps section below for more details
|
||||
on how consumers refer to cooling devices.
|
||||
|
||||
Optional properties:
|
||||
- cooling-min-level: An integer indicating the smallest
|
||||
Type: unsigned cooling state accepted. Typically 0.
|
||||
Size: one cell
|
||||
|
||||
- cooling-max-level: An integer indicating the largest
|
||||
Type: unsigned cooling state accepted.
|
||||
Size: one cell
|
||||
|
||||
* Trip points
|
||||
|
||||
The trip node is a node to describe a point in the temperature domain
|
||||
|
@ -226,8 +216,6 @@ cpus {
|
|||
396000 950000
|
||||
198000 850000
|
||||
>;
|
||||
cooling-min-level = <0>;
|
||||
cooling-max-level = <3>;
|
||||
#cooling-cells = <2>; /* min followed by max */
|
||||
};
|
||||
...
|
||||
|
@ -241,8 +229,6 @@ cpus {
|
|||
*/
|
||||
fan0: fan@48 {
|
||||
...
|
||||
cooling-min-level = <0>;
|
||||
cooling-max-level = <9>;
|
||||
#cooling-cells = <2>; /* min followed by max */
|
||||
};
|
||||
};
|
||||
|
|
Loading…
Reference in New Issue