ARM: BCM5301X: Ignore another (BCM4709 specific) fault code
Broadcom ARM devices seem to generate some fault once per boot. We already have an ignoring handler for BCM4707/BCM4708, but BCM4709 generates different code. Signed-off-by: Rafał Miłecki <zajec5@gmail.com> Signed-off-by: Florian Fainelli <f.fainelli@gmail.com>
This commit is contained in:
parent
b787f68c36
commit
7eb68a2a05
|
@ -18,15 +18,16 @@ static bool first_fault = true;
|
|||
static int bcm5301x_abort_handler(unsigned long addr, unsigned int fsr,
|
||||
struct pt_regs *regs)
|
||||
{
|
||||
if (fsr == 0x1c06 && first_fault) {
|
||||
if ((fsr == 0x1406 || fsr == 0x1c06) && first_fault) {
|
||||
first_fault = false;
|
||||
|
||||
/*
|
||||
* These faults with code 0x1c06 happens for no good reason,
|
||||
* possibly left over from the CFE boot loader.
|
||||
* These faults with codes 0x1406 (BCM4709) or 0x1c06 happens
|
||||
* for no good reason, possibly left over from the CFE boot
|
||||
* loader.
|
||||
*/
|
||||
pr_warn("External imprecise Data abort at addr=%#lx, fsr=%#x ignored.\n",
|
||||
addr, fsr);
|
||||
addr, fsr);
|
||||
|
||||
/* Returning non-zero causes fault display and panic */
|
||||
return 0;
|
||||
|
|
Loading…