staging: comedi: das800: interrupts are required for async command support
Interrupt support is optional with this driver. Only hook up the async command support for the analog input subdevice if the user requested an interrupt when attaching to the board. This also allows removing the extra test in das800_ai_do_cmd(). For aesthetic reasons, add some whitespace to the subdevice init. Signed-off-by: H Hartley Sweeten <hsweeten@visionengravers.com> Reviewed-by: Ian Abbott <abbotti@mev.co.uk> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
This commit is contained in:
parent
2bc405831d
commit
77630119ba
|
@ -412,12 +412,6 @@ static int das800_ai_do_cmd(struct comedi_device *dev,
|
|||
unsigned long irq_flags;
|
||||
struct comedi_async *async = s->async;
|
||||
|
||||
if (!dev->irq) {
|
||||
comedi_error(dev,
|
||||
"no irq assigned for das-800, cannot do hardware conversions");
|
||||
return -1;
|
||||
}
|
||||
|
||||
disable_das800(dev);
|
||||
|
||||
/* set channel scan limits */
|
||||
|
@ -768,15 +762,18 @@ static int das800_attach(struct comedi_device *dev, struct comedi_devconfig *it)
|
|||
s = &dev->subdevices[0];
|
||||
dev->read_subdev = s;
|
||||
s->type = COMEDI_SUBD_AI;
|
||||
s->subdev_flags = SDF_READABLE | SDF_GROUND | SDF_CMD_READ;
|
||||
s->subdev_flags = SDF_READABLE | SDF_GROUND;
|
||||
s->n_chan = 8;
|
||||
s->len_chanlist = 8;
|
||||
s->maxdata = (1 << thisboard->resolution) - 1;
|
||||
s->range_table = thisboard->ai_range;
|
||||
s->do_cmd = das800_ai_do_cmd;
|
||||
s->do_cmdtest = das800_ai_do_cmdtest;
|
||||
s->insn_read = das800_ai_rinsn;
|
||||
if (dev->irq) {
|
||||
s->subdev_flags |= SDF_CMD_READ;
|
||||
s->len_chanlist = 8;
|
||||
s->do_cmdtest = das800_ai_do_cmdtest;
|
||||
s->do_cmd = das800_ai_do_cmd;
|
||||
s->cancel = das800_cancel;
|
||||
}
|
||||
|
||||
/* di */
|
||||
s = &dev->subdevices[1];
|
||||
|
|
Loading…