PM / OPP: opp-microvolt is not optional if regulators are set

If dev_pm_opp_set_regulators() is called for a device and its regulators
are set in the OPP core, the OPP nodes for the device must contain the
"opp-microvolt" property, otherwise there is something wrong and we
better error out.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Reviewed-by: Stephen Boyd <sboyd@codeaurora.org>
Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
This commit is contained in:
Viresh Kumar 2017-05-23 09:32:12 +05:30 committed by Rafael J. Wysocki
parent 478256bddb
commit 688a48b0d2
1 changed files with 8 additions and 2 deletions

View File

@ -131,8 +131,14 @@ static int opp_parse_supplies(struct dev_pm_opp *opp, struct device *dev,
prop = of_find_property(opp->np, name, NULL);
/* Missing property isn't a problem, but an invalid entry is */
if (!prop)
return 0;
if (!prop) {
if (!opp_table->regulator_count)
return 0;
dev_err(dev, "%s: opp-microvolt missing although OPP managing regulators\n",
__func__);
return -EINVAL;
}
}
vcount = of_property_count_u32_elems(opp->np, name);