pwm: lp3943: Fix duty calculation in case period was clamped

The hardware only supports periods <= 1.6 ms and if a bigger period is
requested it is clamped to 1.6 ms. In this case duty_cycle might be bigger
than 1.6 ms and then the duty cycle register is written with a value
bigger than LP3943_MAX_DUTY. So clamp duty_cycle accordingly.

Fixes: af66b3c093 ("pwm: Add LP3943 PWM driver")
Signed-off-by: Uwe Kleine-König <u.kleine-koenig@pengutronix.de>
Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
This commit is contained in:
Uwe Kleine-König 2022-04-08 17:22:38 +02:00 committed by Thierry Reding
parent b3c4af8507
commit 5e3b07ca5c
1 changed files with 1 additions and 0 deletions

View File

@ -125,6 +125,7 @@ static int lp3943_pwm_config(struct pwm_chip *chip, struct pwm_device *pwm,
if (err)
return err;
duty_ns = min(duty_ns, period_ns);
val = (u8)(duty_ns * LP3943_MAX_DUTY / period_ns);
return lp3943_write_byte(lp3943, reg_duty, val);