hwmon: (lm90) Prevent integer overflow/underflow in hysteresis calculations
Commitb50aa49638
("hwmon: (lm90) Prevent integer underflows of temperature calculations") addressed a number of underflow situations when writing temperature limits. However, it missed one situation, seen when an attempt is made to set the hysteresis value to MAX_LONG and the critical temperature limit is negative. Use clamp_val() when setting the hysteresis temperature to ensure that the provided value can never overflow or underflow. Fixes:b50aa49638
("hwmon: (lm90) Prevent integer underflows of temperature calculations") Cc: Dmitry Osipenko <digetx@gmail.com> Reviewed-by: Dmitry Osipenko <digetx@gmail.com> Signed-off-by: Guenter Roeck <linux@roeck-us.net>
This commit is contained in:
parent
fce15c45d3
commit
55840b9eae
|
@ -1160,8 +1160,8 @@ static int lm90_set_temphyst(struct lm90_data *data, long val)
|
|||
else
|
||||
temp = temp_from_s8(data->temp8[LOCAL_CRIT]);
|
||||
|
||||
/* prevent integer underflow */
|
||||
val = max(val, -128000l);
|
||||
/* prevent integer overflow/underflow */
|
||||
val = clamp_val(val, -128000l, 255000l);
|
||||
|
||||
data->temp_hyst = hyst_to_reg(temp - val);
|
||||
err = i2c_smbus_write_byte_data(client, LM90_REG_W_TCRIT_HYST,
|
||||
|
|
Loading…