ASoC: pcm186x: Fix device reset-registers trigger value
According to the current device datasheet (TI Lit # SLAS831D, revised March 2018) the value written to the device's PAGE register to trigger a complete register reset should be 0xfe, not 0xff. So go ahead and update to the correct value. Reported-by: Stephane Le Provost <stephane.leprovost@mediatek.com> Tested-by: Stephane Le Provost <stephane.leprovost@mediatek.com> Signed-off-by: Andreas Dannenberg <dannenberg@ti.com> Acked-by: Andrew F. Davis <afd@ti.com> Signed-off-by: Mark Brown <broonie@kernel.org> Cc: stable@vger.kernel.org
This commit is contained in:
parent
882eab6c28
commit
5277715639
|
@ -139,7 +139,7 @@ enum pcm186x_type {
|
|||
#define PCM186X_MAX_REGISTER PCM186X_CURR_TRIM_CTRL
|
||||
|
||||
/* PCM186X_PAGE */
|
||||
#define PCM186X_RESET 0xff
|
||||
#define PCM186X_RESET 0xfe
|
||||
|
||||
/* PCM186X_ADCX_INPUT_SEL_X */
|
||||
#define PCM186X_ADC_INPUT_SEL_POL BIT(7)
|
||||
|
|