bnx2x: Add warning message in case of non-10G SFP module
The string was split to several lines since it reached over 180 chars, which seems too much. Signed-off-by: Yaniv Rosner <yanivr@broadcom.com> Signed-off-by: Eilon Greenstein <eilong@broadcom.com> Signed-off-by: David S. Miller <davem@davemloft.net>
This commit is contained in:
parent
503976e998
commit
52160da71a
|
@ -7986,9 +7986,8 @@ static int bnx2x_get_edc_mode(struct bnx2x_phy *phy,
|
||||||
{
|
{
|
||||||
struct bnx2x *bp = params->bp;
|
struct bnx2x *bp = params->bp;
|
||||||
u32 sync_offset = 0, phy_idx, media_types;
|
u32 sync_offset = 0, phy_idx, media_types;
|
||||||
u8 val[2], check_limiting_mode = 0;
|
u8 gport, val[2], check_limiting_mode = 0;
|
||||||
*edc_mode = EDC_MODE_LIMITING;
|
*edc_mode = EDC_MODE_LIMITING;
|
||||||
|
|
||||||
phy->media_type = ETH_PHY_UNSPECIFIED;
|
phy->media_type = ETH_PHY_UNSPECIFIED;
|
||||||
/* First check for copper cable */
|
/* First check for copper cable */
|
||||||
if (bnx2x_read_sfp_module_eeprom(phy,
|
if (bnx2x_read_sfp_module_eeprom(phy,
|
||||||
|
@ -8043,8 +8042,15 @@ static int bnx2x_get_edc_mode(struct bnx2x_phy *phy,
|
||||||
SFP_EEPROM_COMP_CODE_LR_MASK |
|
SFP_EEPROM_COMP_CODE_LR_MASK |
|
||||||
SFP_EEPROM_COMP_CODE_LRM_MASK)) == 0) {
|
SFP_EEPROM_COMP_CODE_LRM_MASK)) == 0) {
|
||||||
DP(NETIF_MSG_LINK, "1G Optic module detected\n");
|
DP(NETIF_MSG_LINK, "1G Optic module detected\n");
|
||||||
|
gport = params->port;
|
||||||
phy->media_type = ETH_PHY_SFP_1G_FIBER;
|
phy->media_type = ETH_PHY_SFP_1G_FIBER;
|
||||||
phy->req_line_speed = SPEED_1000;
|
phy->req_line_speed = SPEED_1000;
|
||||||
|
if (!CHIP_IS_E1x(bp))
|
||||||
|
gport = BP_PATH(bp) + (params->port << 1);
|
||||||
|
netdev_err(bp->dev, "Warning: Link speed was forced to 1000Mbps."
|
||||||
|
" Current SFP module in port %d is not"
|
||||||
|
" compliant with 10G Ethernet\n",
|
||||||
|
gport);
|
||||||
} else {
|
} else {
|
||||||
int idx, cfg_idx = 0;
|
int idx, cfg_idx = 0;
|
||||||
DP(NETIF_MSG_LINK, "10G Optic module detected\n");
|
DP(NETIF_MSG_LINK, "10G Optic module detected\n");
|
||||||
|
|
Loading…