iio: humidity: hts221: Use dev_get_platdata() to get platform_data
Use dev_get_platdata() to get the platform_data instead of referencing it directly. Signed-off-by: Andy Shevchenko <andriy.shevchenko@linux.intel.com> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
This commit is contained in:
parent
38bc80154a
commit
4d8d2f09ad
|
@ -74,10 +74,10 @@ static irqreturn_t hts221_trigger_handler_thread(int irq, void *private)
|
|||
|
||||
int hts221_allocate_trigger(struct hts221_hw *hw)
|
||||
{
|
||||
struct st_sensors_platform_data *pdata = dev_get_platdata(hw->dev);
|
||||
struct iio_dev *iio_dev = iio_priv_to_dev(hw);
|
||||
bool irq_active_low = false, open_drain = false;
|
||||
struct device_node *np = hw->dev->of_node;
|
||||
struct st_sensors_platform_data *pdata;
|
||||
unsigned long irq_type;
|
||||
int err;
|
||||
|
||||
|
@ -106,7 +106,6 @@ int hts221_allocate_trigger(struct hts221_hw *hw)
|
|||
if (err < 0)
|
||||
return err;
|
||||
|
||||
pdata = (struct st_sensors_platform_data *)hw->dev->platform_data;
|
||||
if ((np && of_property_read_bool(np, "drive-open-drain")) ||
|
||||
(pdata && pdata->open_drain)) {
|
||||
irq_type |= IRQF_SHARED;
|
||||
|
|
Loading…