dt-bindings: memory: tegra20: emc: Replace core regulator with power domain

Power domain fits much better than a voltage regulator in regards to
a proper hardware description and from a software perspective as well.
Hence replace the core regulator with the power domain. Note that this
doesn't affect any existing DTBs because we haven't started to use the
regulator yet, and thus, it's okay to change it.

Signed-off-by: Dmitry Osipenko <digetx@gmail.com>
Reviewed-by: Rob Herring <robh@kernel.org>
Link: https://lore.kernel.org/r/20210330230445.26619-2-digetx@gmail.com
Signed-off-by: Krzysztof Kozlowski <krzysztof.kozlowski@canonical.com>
This commit is contained in:
Dmitry Osipenko 2021-03-31 02:04:40 +03:00 committed by Krzysztof Kozlowski
parent f012ade8aa
commit 4be3973c00
1 changed files with 2 additions and 2 deletions

View File

@ -23,7 +23,7 @@ For each opp entry in 'operating-points-v2' table:
matches, the OPP gets enabled.
Optional properties:
- core-supply: Phandle of voltage regulator of the SoC "core" power domain.
- power-domains: Phandle of the SoC "core" power domain.
Child device nodes describe the memory settings for different configurations and clock rates.
@ -48,7 +48,7 @@ Example:
interrupts = <0 78 0x04>;
clocks = <&tegra_car TEGRA20_CLK_EMC>;
nvidia,memory-controller = <&mc>;
core-supply = <&core_vdd_reg>;
power-domains = <&domain>;
operating-points-v2 = <&opp_table>;
}