s390/compat: correct check for EFAULT in rt-signal frame creation

The return code of the __put_user call to store the rt_sigreturn
system call to the user stack if not properly checked, the err
variable is only checked before to the __put_user. Use an if
statement instead.

Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
This commit is contained in:
Martin Schwidefsky 2013-12-10 16:18:07 +01:00
parent 96619fc1b3
commit 41932bc1c8
1 changed files with 3 additions and 2 deletions

View File

@ -412,8 +412,9 @@ static int setup_rt_frame32(int sig, struct k_sigaction *ka, siginfo_t *info,
regs->gprs[14] = (__u64 __force) ka->sa.sa_restorer | PSW32_ADDR_AMODE;
} else {
regs->gprs[14] = (__u64 __force) frame->retcode | PSW32_ADDR_AMODE;
err |= __put_user(S390_SYSCALL_OPCODE | __NR_rt_sigreturn,
(u16 __force __user *)(frame->retcode));
if (__put_user(S390_SYSCALL_OPCODE | __NR_rt_sigreturn,
(u16 __force __user *)(frame->retcode)))
goto give_sigsegv;
}
/* Set up backchain. */